Additional results for 'Sequential design approaches for bioequivalence studies with crossover designs'.
نویسندگان
چکیده
In 2008, this group published a paper on approaches for two-stage crossover bioequivalence (BE) studies that allowed for the reestimation of the second-stage sample size based on the variance estimated from the first-stage results. The sequential methods considered used an assumed GMR of 0.95 as part of the method for determining power and sample size. This note adds results for an assumed GMR = 0.90. Two of the methods recommended for GMR = 0.95 in the earlier paper have some unacceptable increases in Type I error rate when the GMR is changed to 0.90. If a sponsor wants to assume 0.90 for the GMR, Method D is recommended. Copyright © 2011 John Wiley & Sons, Ltd.
منابع مشابه
On statistical power for average bioequivalence testing under replicated crossover designs.
In its recent guidance on bioequivalence, the U.S. Food and Drug Administration (FDA) recommends a two-sequence, four-period (2 x 4) replicated crossover design be used for assessment of population and individual bioequivalence [FDA. Guidance for Industry on Statistical Approaches to Establishing Bioequivalence; Center for Drug Evaluation and Research, Food and Drug Administration: Rockville, M...
متن کاملSample size calculation for bioequivalence studies with high-order crossover designs.
Exact power and sample size calculation for bioequivalence studies with high order crossover designs using statistical software nQuery are presented. Such calculation can be very easily performed, and thus provides a convenient tool for practical usage.
متن کاملBioequivalence Studies of Two Formulations of Baclofen Tablet in Healthy Volunteers
The relative bioavailability of the test (generic) product 2 × 25 mg baclofen tablets, with respect to the reference product, Lioresal® 2 × 25 mg tablets (baclofen; Squibb) was determined in a single-blind, single dose, randomised, crossover study. The mean values for the variable Cmax were 737.6 ng/ml for the reference and 739.5 ng/ml for the test product. The mean values for the variable AUC ...
متن کاملDetermination of sample size for two stage sequential designs in bioequivalence studies under 2x2 crossover design
Sequential design is an adaptive design that allows for pre-mature termination of a trial due to efficacy or futility based on the interim analyses. The concept of sequential statistical methods was originally motivated by the need to obtain clinical benefits under certain economic constraints. That is for a trial for a positive results, early stopping ensures that a new drug product can exploi...
متن کاملBioequivalence Studies of Two Formulations of Baclofen Tablet in Healthy Volunteers
The relative bioavailability of the test (generic) product 2 × 25 mg baclofen tablets, with respect to the reference product, Lioresal® 2 × 25 mg tablets (baclofen; Squibb) was determined in a single-blind, single dose, randomised, crossover study. The mean values for the variable Cmax were 737.6 ng/ml for the reference and 739.5 ng/ml for the test product. The mean values for the variable AUC ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Pharmaceutical statistics
دوره 11 1 شماره
صفحات -
تاریخ انتشار 2008