Needle Force Sensor, Robust and Sensitive Detection of the Instant of Needle Puncture

نویسندگان

  • Toshikatsu Washio
  • Kiyoyuki Chinzei
چکیده

A force sensor based method to detect the instant of needle puncture to the layers of tissues is proposed. A set of needle and sheath attached to a pair of coaxial force sensors was used to separately measure the cutting force at the needle tip and the sidewall friction. Change of the force profile was observed and marked at the instant of the puncture, and robustly eliminated artifacts caused by body motion such as the respiratory or cardiac motion. The agreement between the subjective feeling of a skilled surgeon and the sensor was good. In several cases the sensor detected the puncture even when the surgeon could not clearly identify it. It was suggested that the sensor is potentially more sensitive than skilled professionals.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Needle Tumor Puncture Detection Using a Force and Position Sensor

Preforming a tumor ablation procedure involves precisely positioning an ablation probe in a tumor. Limited sensing accuracy and variations in tissue properties require that surgeons often identify when they have correctly positioned the probe through their sense of touch. In this paper, supervised learning is used to detect the point at which a needle has entered a tumor using a combination of ...

متن کامل

Post spinal puncture headache, an old problem and new concepts: review of articles about predisposing factors

Post spinal puncture headache (PSPH) is a well known complication of spinal anesthesia. It occurs after spinal anesthesia induction due to dural and arachnoid puncture and has a significant effect on the patient’s postoperative well being. This manuscript is based on an observational study that runs on Babol University of Medical Sciences and review of literatures about current concepts about t...

متن کامل

MARGE Project: Design, Modeling, and Control of Assistive Devices for Minimally Invasive Surgery

Crawling on the heart : a mobile robotic device for minimally invasive cardiac interventions p. 9 High dexterity snake-like robotic slaves for minimally invasive telesurgery of the upper airway p. 17 Development of a robotic laser surgical tool with an integrated video endoscope p. 25 Micro-neurosurgical system in the deep surgical field p. 33 Dense 3D depth recovery for soft tissue deformation...

متن کامل

Effects of Rotational Motion in Robotic Needle Insertion

Background: Robotic needle insertion in biological tissues has been known as one the most applicable procedures in sampling, robotic injection and different medical therapies and operations.Objective: In this paper, we would like to investigate the effects of angular velocity in soft tissue insertion procedure by considering force-displacement diagram. Non-homogenous camel liver can be exploite...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2004