Combined quantitative analysis of attenuation corrected and non-corrected myocardial perfusion SPECT: Method development and clinical validation.

نویسندگان

  • Yuan Xu
  • Mathews Fish
  • James Gerlach
  • Mark Lemley
  • Daniel S Berman
  • Guido Germano
  • Piotr J Slomka
چکیده

BACKGROUND Attenuation corrected myocardial perfusion SPECT (AC-MPS) has been demonstrated to improve the specificity of detecting coronary artery disease (CAD) by visual analysis which utilizes both non-corrected (NC) and AC data. However, the combined automated quantification of NC and AC-MPS has not been previously described. We aimed to develop a combined quantitative analysis from AC and NC data to improve the accuracy of automated detection of CAD from AC-MPS. METHODS Stress total perfusion deficit (TPD) values were generated by standard analysis for NC (NC-TPD), AC (AC-TPD) and by combined NC-AC analysis (NA-TPD), in which the hypoperfusion severity in each polar map location was defined as the average of AC and NC severity computed by comparison with separate AC and NC normal limits. Ischemic TPD was also calculated as the difference between stress TPD and rest TPD for each measure. Stress/rest Tc-99m sestamibi MPS studies in 650 patients with correlating coronary angiography and in 345 patients with a low-likelihood (LLk) of CAD were used to assess diagnostic performance of combined NC-AC analysis. RESULTS NA-TPD had a higher receiver-operator-characteristic area under the curve (ROC-AUC) (0.87) than NC-TPD (0.85; P < .01) or AC-TPD (0.85; P < .01) for detection of stenosis >or=70% in angiographic group. It also had higher specificity (75%) vs NC-TPD (65%; P < .0001), or AC-TPD (70%; P = .016). In LLk group, the normalcy rate of NA-TPD (95%) was higher than for NC-TPD (90%; P < .01) and similar to AC-TPD (94%; P = NS). NA-TPD had higher ROC-AUC than that for 17-segment expert visual scoring of stress scans in angiographic group (0.84; P = .01), comparable accuracy (81%) and similar normalcy rates (95% vs 97%; P = NS). Ischemic TPD by combined NC-AC analysis had higher ROC-AUC than that for any ischemic measure. Similar to stress NA-TPD, it also obtained the similar performance results as compared with ischemic TPD based on NC or AC and higher sensitivity (89% vs 85%; P = .0295) as compared with ischemic visual score in angiographic group. CONCLUSION Combined NC-AC MPS quantification using either stress or ischemic TPD shows significant improvements for ROC-AUC and specificity of MPS in the detection of CAD compared with standard NC-MPS or AC-MPS and comparable performance to expert visual scoring. This technique may lead to an enhancement in a fully automated quantification for the perfusion analysis by AC-MPS.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Attenuation correction in myocardial perfusion SPECT using sequential transmission - emission scanning with 99mTc [Persain]

Introduction: Nowadays, Imaging of the myocardial perfusion (MPI) using the single photon emission tomography (SPET) in the diagnosis of coronary artery disease, especially myocardial ischemia, is of great importance. In contrast to the coronary artery angiography, MPI is non-invasive, less expensive and more physiological. Unfortunately, this image is affected by the some artifacts. Thes...

متن کامل

Evaluation of attenuation correction process in cardiac SPECT images

  Introduction: Attenuation correction is a useful process for improving myocardial perfusion SPECT and is dependent on activity and distribution of attenuation coefficients in the body (attenuation map). Attenuation artifacts are a common problem in myocardial perfusion SPECT. The aim of this study was to compare the effect of attenuation correction using different a...

متن کامل

New approach for attenuation correction in SPECT images, using linear optimization

Background: Photon attenuation as an inevitable physical phenomenon influences on the diagnostic information of SPECT images and results to errors in accuracy of quantitative measurements. This can be corrected via different physical or mathematical approaches. As the correction equation in mathematical approaches is nonlinear, in this study a new method of linearization called ‘Piece ...

متن کامل

Comparison of transient ischemic dilation ratios in SPECT and SPECT-CT myocardial perfusion imaging in the low pre-test probability group

Introduction: The main purpose of this study was to compare transient ischemic dilation (TID) ratios in SPECT-low dose CT and SPECT Myocardial Perfusion Imaging (MPI) by application of different quantitative programs and quantify the possible shift in the upper normal limits of TID ratio in the SPECT-CT MPI. Methods: 149 Patients with low pre-test probability for coronary artery disease (CAD),...

متن کامل

Assessment of the impact of applying attenuation correction on the accuracy of activity recovery in Tc99m-ECD brain SPECT of healthy subject using Statistical Parametric Mapping (SPM)

Introduction: Photon attenuation in tissues is the primary physical degrading factor limiting both visual qualitative interpretation and quantitative analysis capabilities of reconstructed Single Photon Emission Computed Tomography (SPECT) images. The aim of present study was to investigate the effect of attenuation correction on the detection of activation foci following statistical analysis w...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of nuclear cardiology : official publication of the American Society of Nuclear Cardiology

دوره 17 4  شماره 

صفحات  -

تاریخ انتشار 2010