Risk Factors for Intraoperative Proximal Femoral Fracture During Primary Cementless THA.
نویسندگان
چکیده
Intraoperative proximal femoral fracture, one of the most common complications of total hip arthroplasty (THA), occurs more often in cementless procedures and can affect rehabilitation, hospitalization time, and cost of treatment. The goal of this study was to identify risk factors for intraoperative proximal femoral fracture in THA to identify high-risk groups preoperatively and minimize the incidence of this complication. This nested case-control study included 904 primary cementless THA procedures (769 patients) performed between January 2009 and July 2015. Of this group, 24 fractures occurred, accounting for 2.65% of cases. Predisposing factors for intraoperative proximal femoral fracture from the medical records included patient sex, diagnosis of osteoarthritis, operated on hip (left or right), type of implant, alcohol consumption, operative approach, age, and body mass index. The Noble classification, Dorr classification, and Metaphyseal-Diaphyseal Index score measured by picture archiving and communication systems were used to evaluate the anatomy and morphologic features of the proximal femur. A multivariate analysis was performed to evaluate potential risk factors for fracture during THA, including anterolateral (modified Hardinge) approach, use of the Corail (DePuy, Warsaw, Indiana) stem, Metaphyseal-Diaphyseal Index score, age, and sex. A Corail stem, the anterolateral approach, advanced age, and a low Metaphyseal-Diaphyseal Index score were associated with increased risk of fracture. All fractures were treated with cerclage wire techniques, and none has required revision to date. [Orthopedics. 2017; 40(2):e281-e287.].
منابع مشابه
Risk factors for intraoperative calcar fracture in cementless total hip arthroplasty.
BACKGROUND AND PURPOSE Intraoperative periprosthetic femoral fracture is a known complication of cementless total hip arthroplasty (THA). We determined the incidence of--and risk factors for--intraoperative calcar fracture, and assessed its influence on the risk of revision. PATIENTS AND METHODS This retrospective analysis included 3,207 cementless THAs (in 2,913 patients). 118 intraoperative...
متن کاملCementless Total Hip Arthroplasty After an Iatrogenic Subtrochanteric Fracture due to Hardware Removal: A Case Report
Introduction: Total hip arthroplasty (THA) after proximal femoral fixation is a challenging procedure due to possible hardware-related complications. Case presentation: A 78-year-old female with hip osteoarthritis had a proximal femoral osteotomy fixed using a blade plate in the same femur 41 years ago. A two-step approach was planned. After a challenging...
متن کاملComparison of Specific Femoral Short Stems and Conventional-Length Stems in Primary Cementless Total Hip Arthroplasty.
There are several reported disadvantages with conventional-length femoral stems in cementless total hip arthroplasty (THA). Therefore, various efforts have been made to develop a specific femoral short stem to improve physiologic bone remodeling at the femoral aspect of a cementless THA. However, there are potential disadvantages with specific femoral short stems, such as malalignment, inadvert...
متن کاملClinical characteristics and risk factors of periprosthetic femoral fractures associated with hip arthroplasty
Periprosthetic femoral fracture (PFF) is a complicated complication of both primary and revision hip arthroplasty with an increasing incidence. The present study aimed to summarize the clinical characteristics and identify the risk factors for PFF which would be potentially helpful in the prevention and treatment of PFF.We retrospectively analyzed the clinical data of 89 cases of PFF, and a cas...
متن کاملPelvic Discontinuity Caused by Acetabular Overreaming during Primary Total Hip Arthroplasty
Intraoperative acetabular fracture is a rare complication of primary total hip arthroplasty (THA), typically occurring during impaction of the cementless acetabular component. Here we report an unusual case of pelvic discontinuity caused by overreaming of the acetabulum during primary THA. Restoration of posterior columnar continuity was achieved with an autologous fibular graft and a reconstru...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Orthopedics
دوره 40 2 شماره
صفحات -
تاریخ انتشار 2017