Optical fibre sensors: their role in in vivo dosimetry for prostate cancer radiotherapy
نویسندگان
چکیده
Review is made of dosimetric studies of current optical fibre technology in radiotherapy for therapeutic applications, focusing particularly on in vivo dosimetry for prostate radiotherapy. We present the various sensor designs along with the main advantages and disadvantages associated with this technology. Optical fibres are ideally placed for applications in radiotherapy dosimetry; due to their small size they are lightweight and immune to electromagnetic interferences. The small dimensions of optical fibres allows it to be easily guided within existing brachytherapy equipment; for example, within the seed implantation needle for direct tumour dose analysis, in the urinary catheter to monitor urethral dose, or within the biopsy needle holder of the transrectal ultrasound probe to monitor rectal wall dose. The article presents the range of optical fibre dosimeter designs along with the main dosimetric properties required for a modern in vivo dosimetry system to be utilised in a clinical environment.
منابع مشابه
Verification of the Accuracy of the Delivered Dose in Pelvic and Breast Cancer Radiotherapy by in-vivo Semi-Conductor Dosimetry
Introduction: Delivering maximum dose to tumor and minimum dose to normal tissues is the most important goal in radiotherapy. According to ICRU, the maximum acceptable uncertainty in the delivered dose compared to the prescribed dose should be lower than 5%, and this is because of the relationship between absorbed dose, tumor control and normal tissue damage. Absorbed dose accuracy is investiga...
متن کاملAssessment of a 2D EPID-based Dosimetry Algorithm for Pre-treatment and In-vivo Midplane Dose Verification
Introduction: The use of electronic portal imaging devices (EPIDs) is a method for the dosimetric verification of radiotherapy plans both pretreatment and in-vivo. The aim of this study was to test a 2D EPID-based dosimetry algorithm for dose verification of some plans inside a homogenous and anthropomorphic phantom and in-vivo, as well. Materials and Methods: </strong...
متن کاملA Dosimetric Evaluation of Organs at Risk in Prostate Radiation Therapy using a MAGIC Gel Dosimeter
Introduction: Multiple fields and presence of heterogeneities create complex dose distributions that need three dimensional dosimetry. In this work, we investigated MR-based MAGIC gel dosimetry as a three-dimensional dosimetry technique to measure the delivered dose to bladder and rectum in prostate radiation therapy. Materials and Methods: A heterogeneous slab phantom including bones was made....
متن کاملRectal and Bladder Dose Measurements in the Intracavitary Applications of Cervical Cancer Treatment with HDR Afterloading System: Comparison of TPS Data with MOSFET Detector
Background: Intracavitary brachytherapy plays a major role in management of cervical carcinoma. Assessment of dose received by OAR’s therefore becomes crucial for the estimation of radiation toxicities in HDR brachytherapy. Objective: Purpose of this study is to evaluate the role of in vivo dosimetry in HDR brachytherapy and to compare actual doses delivered to OAR’ s with those calculate...
متن کاملSystemic Targeted Alpha Radiotherapy for Cancer
Background: The fundamental principles of internal targeted alpha therapy for cancer were established many decades ago.The high linear energy transfer (LET) of alpha radiation to the targeted cancer cellscauses double strand breaks in DNA. At the same time, the short range radiation spares adjacent normal tissues. This targeted approach complements conventional external beam radiotherapy and ch...
متن کامل