INTRODUCTION The viability of hearing protection device (HPD) verification (i.e., fit-testing) on a large scale was investigated to address this gap in a military accession environment. MATERIALS AND METHODS Personal Attenuation Ratings (PARs) following self-fitted (SELF-Fit) HPDs were acquired from 320 US Marine Corps training recruits (87.5% male, 12.5% female) across four test protocols (1-, 3-, 5-, and 7- frequency). SELF-Fit failures received follow-up to assess potential causes. Follow-up PARs were acquired (Experimenter fit [EXP-Fit], followed by Subject re-fit [SUB Re-Fit]). EXP-Fit was intended to provide a perception (dubbed "ear canal muscle memory") of what a correctly fitted HPD should feel like. SUB Re-Fit was completed following EXP-Fit to determine whether a training recruit could duplicate EXP-Fit on her/his own without assistance. RESULTS A one-way analysis of variance (ANOVA) (N = 320) showed that SELF-Fit means differed significantly between protocols (P < 0.001). Post-hoc analyses showed that the 1-freq SELF-Fit mean was significantly lower than all other protocols (P < 0.03) by 5.6 dB or more. No difference was found between the multi-frequency protocols. For recruits who were followed up with EXP-Fit (n = 79), across all protocols, a significant (P < 0.001) mean improvement of 25.68 dB (10.99) was found, but PARs did not differ (P = 0.99) between EXP-Fit protocols. For recruits in the 3-freq and 5-freq protocol groups who experienced all three PAR test methods (n = 33), PAR methods differed (P < 0.001) but no method by protocol interaction was found (P = 0.46). Post hoc tests showed that both EXP-Fit and SUB Re-Fit had significantly better attenuation than SELF-Fit (P < 0.001), but no difference was found between EXPFit and SUB Re-Fit (P = 0.59). For SELF-Fit, the 1-freq protocol resulted in a 35% pass rate, whereas the 3-, 5-, and 7-freq protocols resulted in >60% pass rates. Results showed that once recruits experienced how HPDs should feel when inserted correctly, they were able to properly replicate the procedure with similar results to the expert fit suggesting "ear canal muscle memory" may be a viable training strategy concomitant with HPD verification. Fit-test duration was also measured to examine the tradeoff between results accuracy and time required to complete each protocol. DISCUSSION Results from this study showed the critical importance of initial selection and fitting of HPDs followed by verification (i.e., fit-testing) at Navy and Marine Corps accession points. Achieving adequate protection from an HPD is fundamentally dependent on obtaining proper fit of the issued HPD as well as the quality of training recruits receive regarding HPD use.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Engineering out the noise

The US Navy, through an Office of Naval Research (ONR) lead effort on Noise Induced Hearing Loss (NIHL), is investigating methods and techniques to mitigate hearing loss for the crews and warfighters. Hearing protection is a viable and increasingly popular method of reducing hearing exposure for many ship crew members; however, it has limitations on comfort and low frequency effectiveness. Furt...

متن کامل

Report of the Secretary of the Navy

The Navy and Marine Corps provide the Nation with a flexible and joint instrument of security policy with which to promote stability, project maritime power landward, and exercise American sovereignty abroad. Naval forces shape the global security environment; help assure access to regions of vital interest; and permit timely, and frequently, the initial crisis response from the sea. The abilit...

متن کامل

Noise dosimetry for tactical environments

Noise exposure and the subsequent hearing loss are well documented aspects of military life. Numerous studies have indicated high rates of noise-induced hearing injury (NIHI) in active-duty service men and women, and recent statistics from the U.S. Department of Veterans Affairs indicate a population of veterans with hearing loss that is growing at an increasing rate. In an effort to minimize h...

متن کامل

Nurse Corps Manpower Management Model By LCDR Daniel

To increase Navy Nurse Corps manpower management efficiency, we developed a Markov model of the personnel flow of junior officers (O1-O4). The Nurse Corps manages personnel primarily through the recruitment process, drawing on multiple accession sources. Accession sources were shown to have a statistically significant effect on promotion and retention rates. However, these effects were not foun...

متن کامل

Designing and validating a occupational stress management training for navy personnels

Background and aims: Job issues are one of the most important causes of stress. The aim of this study was to design and validate the occupational stress management training for navy personnels. Methods: The present study was a combination of grounded theory and modeling. In the qualitative stage, the statistical population included all industrial-organizational and occupational specialists, se...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 18  شماره 

صفحات  -

تاریخ انتشار 2016