Comparison of the i-gel™ and the Laryngeal Mask Airway Classic™ in terms of clinical performance.
نویسندگان
چکیده
PURPOSE The i-gel™ is one of the second generation supraglottic airway devices. Our study was designed to compare the i-gel and the Laryngeal Mask Airway Classic™ with respect to the clinical performance. METHODS We compared the performance of the i-gel with that of the Laryngeal Mask Airway Classic in 120 patients undergoing urologic surgery during general anesthesia without muscle relaxant with respect to the number of attempts for successful insertion, insertion time, peak airway pressure, incidence of regurgitation, fiberoptic glottic view and postoperative complications. Second generation supraglottic airway devices were inserted by the same anesthesiologist, experienced in use of both devices (>200 uses and first time failure rate <5%). Methylene blue method was used to detect gastric regurgitation. RESULTS There was no statistical difference between the two groups regarding the success of insertion of second generation supraglottic airway device (p=0.951). The laryngeal mask insertion time for the i-gel group was significantly shorter than that for the Laryngeal Mask Airway Classic group (11.6±2.4s versus 13.1±1.8s [p=0.001]). The fiberoptic glottic view scores for the i-gel group was significantly better than that for the ones for the Laryngeal Mask Airway Classic group (p=0.001). On fiberoptic view, there was no sign of methylene blue dye at any time point in either group. In addition, there was no difference between the groups in patient response regarding the presence of a sore throat when questioned 24h after the procedure (p=0.752). CONCLUSION Both devices had good performance with low postoperative complications and without occurrence of regurgitation. The i-gel provided a shorter insertion time and a better fiberoptic view than the Laryngeal Mask Airway Classic.
منابع مشابه
Comparative evaluation of LMA-Supreme and i-gel supraglottic airway devices with endotracheal intubation during surgical correction of traumatic orbital injuries
Aims. The aim of the study was to compare endotracheal intubation with i-gel and LMA (laryngeal mask airway) supreme supraglottic airway devices in orbital osteosynthesis surgery. Methods. 134 patients undergoing orbital plasty after fracture were enrolled in our study and were randomized into three groups: 43 in the endotracheal intubation group, 42 in the LMA-Supreme group, and 49 patients w...
متن کاملComparison of the Incidence of Sore Throat and Hemodynamic Changes in Airway Management by Macintosh, Glideoscope Laryngoscope and Laryngeal Mask Airway Techniques: Randomized Controlled Trial
Background: Studies have shown that postoperative sore throat is the most common complication of tracheal intubation, However, the actual incidence and extent of it are not well documented. Objective: The aim of this study was to evaluate and compare the incidence of sore throat and hemodynamic Changes in Macintosh, Glidescope Laryngoscope and laryngeal mask airway techniques in elective surg...
متن کاملComparison of the effect of thiopental sodium-midazolam combination on the hemodynamic response between tracheal intubation and laryngeal mask airway insertion: A clinical trial study
Background and Aim: The purpose of this study was to compare the effect of thiopental sodium-midazolam combination on the stress response and hemodynamic changes between tracheal intubation and laryngeal mask airway insertion during airway management. Materials and Methods: In this clinical trial study, 70 patients ASA 1, 2 candidates for elective surgery were randomly divided into two groups o...
متن کاملHemodynamic responses to insertion of the laryngeal mask airway versus Combitube
Introduction: One of the most common problems during laryngoscopy involves sympathetic system stimulation and the subsequent hemodynamic changes. It is a key measure to maintain the hemodynamic stability of patients with cardiovascular diseases during induction of anesthesia. This study attempted to compare the hemodynamic effects of laryngeal mask airway and combitube. Methods: This prospec...
متن کاملLimitation of Laryngeal Mask Airway Usage in Open-Neck Procedure
I read the manuscript entitled “Case Report of An Open Neck Procedure Complication Associated with Laryngeal Mask Airway Use” by Subramaniam T et al. This is a valuable manuscript describing iatrogenic complications during level-2 cervical lymph node biopsy, in which the airway is managed with laryngeal mask airway (LMA). During the procedure, the surgeon realized that the mass was actually the...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Revista brasileira de anestesiologia
دوره 65 5 شماره
صفحات -
تاریخ انتشار 2015