Oxidation of ethyl ether on borate glass: chemiluminescence, mechanism, and development of a sensitive gas sensor.

نویسندگان

  • Jing Hu
  • Kailai Xu
  • Yunzhen Jia
  • Yi Lv
  • Yubao Li
  • Xiandeng Hou
چکیده

A gas sensor was developed by using the chemiluminescence (CL) emission from the oxidation of ethyl ether by oxygen in the air on the surface of borate glass. Theoretical calculation, together with experimental investigation, revealed the main CL reactions: ethyl ether is first oxidized to acetaldehyde and then to acetic acid, during which main luminous intermediates such as CH 3CO (*) are generated and emit light with a peak at 493 nm. At a reaction temperature of 245 degrees C, the overall maximal emission was found at around 460 nm, and the linear range of the CL intensity versus the concentration of ethyl ether was 0.12-51.7 microg mL (-1) ( R = 0.999, n = 7) with a limit of detection (3sigma) of 0.04 microg mL (-1). Interference from foreign substances including alcohol (methanol, ethanol and isopropanol), acetone, ethyl acetate, n-hexane, cyclohexane, dichloromethane, or ether ( n-butyl ether, tetrahydrofuran, propylene oxide, isopropyl ether and methyl tert-butyl ether) was not significant except a minimal signal from n-butyl ether (<2%). It is a simple, sensitive and selective gas sensor for the determination of trace ethyl ether.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Performance Evaluation of a Novel Potentiometric Membrane Sensor for Determination of Atorvastatin in Pharmaceutical Preparations

A novel potentiometric ion-selective PVC membrane sensor for analysis of atorvastatin (AT) in pharmaceutical preparations based on atorvastatin-(tetraphenyl borate), (AT-(TPB)2) as sensing element, tetraphenyl borate as additive and tris-2-ethyl-hexyl phosphate (TOP) as plasticizer solvent was prepared. The electrode shows a good Nernestian response over the concentration range of 0.09–5586 µ...

متن کامل

A Sensitive Sensor for Nano-Molar Detection of 5-Fluorouracil by Modifying a Paste Sensor with Graphene Quantum Dots and an Ionic Liquid

5-fluorouracil is a widely used anticancer drug with many side effects on humans, and hence its analysis in biological samples is very important. Accordingly, a novel sensitive electrochemical approach was fabricated by incorporating graphene quantum dots (GCD) and 1-butylpyridinium bromide (BPBr) in the formulation of a carbon paste electrode (GQD/BPBr/CPE). The GQD was synthesized and charact...

متن کامل

Gas Sensor Based on Large Hollow-Core Photonic Bandgap Fiber

One concern in using photonic band-gap fiber (PBGF) as a gas sensor is the response time. In this type of the gas sensors, response time is the time required for gas to diffuse into the hollow-core. So considering a large hollow-core PBGF (HC-PBGF), the response time can be significantly reduced. But in the large HC-PBGF, the fundamental issue is the presence of higher order modes (HOMs). Somet...

متن کامل

Performance Evaluation of a Novel Potentiometric Membrane Sensor for Determination of Atorvastatin in Pharmaceutical Preparations

A novel potentiometric ion-selective PVC membrane sensor for analysis of atorvastatin (AT) in pharmaceutical preparations based on atorvastatin-(tetraphenyl borate), (AT-(TPB)2) as sensing element, tetraphenyl borate as additive and tris-2-ethyl-hexyl phosphate (TOP) as plasticizer solvent was prepared. The electrode shows a good Nernestian response over the concentration range of 0.09–5586 µ...

متن کامل

Design and Simulation of a New Highly Sensitive Gas Sensor Based on Negative Refraction Photonic Crystal

In this paper, design and simulation of a new highly sensitive gas sensor based on a hybrid photonic crystal (PC) structure, containing negative and positive refractive index sections, is presented. It has been shown that using a PC with negative refraction in the first section, the transmitted power is concentrated on the entrance of the sensing channel, and the transmission of the proposed se...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Analytical chemistry

دوره 80 21  شماره 

صفحات  -

تاریخ انتشار 2008