Cochlear implants and 1.5 T MRI scans: the effect of diametrically bipolar magnets and screw fixation on pain

نویسندگان

  • Ingo Todt
  • Grit Rademacher
  • Gloria Grupe
  • Andreas Stratmann
  • Arne Ernst
  • Sven Mutze
  • Philipp Mittmann
چکیده

BACKGROUND The probability that a patient will need an MRI scan at least once in a lifetime is high. However, MRI scanning in cochlear implantees is associated with side effects. Moreover, MRI scan-related artifacts, dislodging magnets, and pain are often the most frequent complications. The aim of this study was to evaluate the occurrence of pain in patients with cochlear implant systems using 1.5T MRI scans. METHODS In a prospective case study of 10 implantees, an MRI scan was performed and the degree of pain was evaluated by a visual analog scale. Scans were performed firstly with and depending on the degree of discomfort/pain, without a headband. Four of the cochlear implants contained a screw fixation. Six cochlear implants contained an internal diametrically bipolar magnet. MRI observations were performed with a 1.5 T scanner. RESULTS MRI scans were performed on all patients without causing any degree of pain, even without the use of a headband. CONCLUSION Patients undergoing 1.5 T MRIs with devices including a diametrically bipolar magnet or a rigid implant screw fixation, experienced no pain, even without headbands.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Adverse events and discomfort during magnetic resonance imaging in cochlear implant recipients.

IMPORTANCE Patients with cochlear implants (CIs) should be fully informed before undergoing magnetic resonance imaging (MRI) about the possibility of discomfort or pain. Prior to an MRI scan, patients need to fully understand not only the potential complications but also the potential discomfort that they may experience during the scan. OBJECTIVE To assess the adverse events during MRI in pat...

متن کامل

Comparison of Intertrochanteric Fracture Fixation with Dynamic Hip Screw and Bipolar Hemiarthroplasty Techniques

Background: At present, there is no consensus on an appropriate treatment modality for intertrochanteric fractures in the elderly with background diseases. The aim of the present study was to compare treatment outcomes of intertrochanteric fractures reduced with dynamic hip screws (DHS) and bipolar hemiarthroplasty in elderly patients with background medical conditions. Methods: In this randomi...

متن کامل

Diagnostic value of CT and MRI of Temporal Bone in Cochlear Implantation Candidates

Background Cochlear implantation is an approved treatment which can be used to treat severe to profound hearing loss. Imaging before cochlear implant surgery is very important in decision making and assessing the temporal bone anatomy for surgery. We aimed to assess the diagnostic value of high resolution CT scan (HRCT), and MRI of temporal bone in candidate pati...

متن کامل

Magnetic resonance imaging and cochlear implants: compatibility and safety aspects.

With cochlear implants, magnetic resonance imaging (MRI) has until recently been contraindicated due to excessive magnetic and electromagnetic interference. The aim of this study was to determine the MRI compatibility of the Med-E1 Combi 40/40+ cochlear implant, within a wide range of clinical MRI applications. In vitro experiments on a 1.5 T MR scanner were performed. Torque, force, demagnetiz...

متن کامل

Magnet Dislocation: An Increasing and Serious Complication Following MRI in Patients with Cochlear Implants Magnetdislokation – eine zunehmende und folgenreiche Komplikation nach MRT bei Patienten mit Cochlea Implantat

Purpose: Cochlear implantation (CI) represents the gold standard in the treatment of children born deaf and postlingually deafened adults. Initial magnetic resonance imaging (MRI) was contraindicated in CI users. Meanwhile, there are specific recommendations concerning MRI compatibility depending on the type of CI system and the device manufacturer. Some CI systems are even approved for MRI wit...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 47  شماره 

صفحات  -

تاریخ انتشار 2018