Three-Dimensional Templating for Acetabular Component Alignment During Total Hip Arthroplasty.

نویسندگان

  • Ameer M Elbuluk
  • Paul Wojack
  • Nima Eftekhary
  • Jonathan M Vigdorchik
چکیده

Appropriate placement of the acetabular cup is an important determinant of implant stability and longevity. Malposition of acetabular cups negatively influences prosthesis survival and leads to an increased dislocation rate. The objective of the study was to determine the role of 3-dimensional templating in obtaining accurate acetabular component placement in total hip arthroplasty. In this computed tomography-based study, the authors identified 93 patients who underwent primary total hip arthroplasty with computer-assisted navigation. Using 3-dimensional planning, the authors templated the acetabular component at an inclination of 40° and anteversion of 20°. To classify acetabular cup coverage by bone, the acetabulum was used as a clock face with the center of the transverse acetabular ligament (TAL) as 6-o'clock. Analyses revealed that 72% of cups were uncovered between 9- to 1-o'clock for right hips. On the left side, 88% of cups were uncovered between 11- to 3-o'clock. Across all hips, 74% of cups had a 1-o'clock position at the most lateral aspect. Further analysis revealed that 46% of acetabular cups had a teardrop at the same level of the most inferior aspect of the cup, whereas only 37% of cups had a teardrop above the inferior aspect of the cup. Finally, the acetabular component was aligned with the TAL in 76% of hips, retroverted to the TAL in 16%, and anteverted to the TAL in 8%. The current study demonstrates a useful gross intraoperative reference tool to standardize cup position without the need for additional equipment and reliance on anatomical landmarks. [Orthopedics. 2017; 40(4):e708-e713.].

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A challenge on Orthopedic Sciences: The Influence of Spinal Disease and Deformities on Total Hip Arthroplasty: A Review on Literature

Background: Adult degenerative disorders of hip and spine are common. The recent studies inconsistently havediscussed about the influence of spinal disorders on total hip arthroplasty (THA). In this review, we discussed clearlyabout these relationships and their effects on the most appropriate position of the acetabular component.Methods: We searched on databases and evaluated the articles abou...

متن کامل

Anatomic Anteversion of the Acetabular Component Correlates with Polyethylene Linear Wear in Total Hip Arthroplasty: The Three-Dimensional Numerical Analysis

Background: Although abduction of the acetabular component is considered to predict factors for polyethylene wear attributable to osteolysis, other radiographic factors have yet to be elucidated. The purpose of the present study was to evaluate whether anteversion or change in implantation angle of the acetabular component influences polyethylene linear wear by using standing and supine radiogr...

متن کامل

Hip Arthroplasty and its Revision in a Child: Case Report and Literature Review

Juvenile idiopathic arthritis is the leading cause of hip replacement in young children. However, arthroplasty in this population is challenging with several concerns about quality of the growing bone, young age for revision surgery, and difficulties in potential several revisions. In this study we introduce a case of a 12-year old who is one of the youngest patients to undergo revision hip art...

متن کامل

Predictive value of preoperative digital templating in THA depends on the surgical experience of the performing physician.

Digital preoperative templating is increasingly used to predict the correct component size in total hip arthroplasty (THA). Experienced surgeons could avoid the new technique and rely on a digital template done by a younger colleague. We compared the accuracy of preoperative templating between orthopedic residents (group A) and an experienced orthopedic surgeon (group B). In 106 cases, the soft...

متن کامل

The accuracy and inter-observer reliability of acetate templating in total hip arthroplasty

AIM The accuracy and inter-observer reliability (IOR) of acetate templating on hard copy X-rays in 33 primary total hip arthroplasties as measured by consultant and trainee surgeons was analyzed to find out how accurate are junior surgeons undertaking specialty training. METHODS The study was questionnaire-based using a prospective cohort over a 4 weeks period. The Surgeon measurements of ace...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Orthopedics

دوره 40 4  شماره 

صفحات  -

تاریخ انتشار 2017