A Remote Operating Slit Lamp Microscope System
نویسندگان
چکیده
N. Tanabe1; K. Go3; Y. Sakurada1; M. Imasawa1; F. Mabuchi1; T. Chiba1; K. Abe4; K. Kashiwagi1,2 1Department of Ophthalmology, University of Yamanashi School of Medicine, Chuo, Yamanashi, Japan; 2Department of Community and Family Medicine Interdisciplinary Graduate School of Medicine and Engineering, University of Yamanashi, Chuo, Yamanashi, Japan; 3Department of Computer Media Engineering, Interdisciplinary Graduate School of Medicine and Engineering, University of Yamanashi, Kofu, Yamanashi, Japan; 4Department of Ophthalmology, Yamanashi Prefectural Central Hospital, Kofu, Yamanashi, Japan
منابع مشابه
Depth measurement with the slit-lamp microscope.
The sagittal distance of ocular structures can be obtained with a slit-lamp microscope providing the movement of the slit-lamp can be measured. A simple device consisting of a pointer attached by a spring clip to the axle of a Haag-Streit 900 slit-lamp is described. The pointer rides over a scale which slides with the slit-lamp. Comparisons of anterior chamber depth and lens thickness showed a ...
متن کاملA simple optical apparatus for measuring the corneal thickness, and the average thickness of the human cornea.
PREVIOUS methods of measuring the corneal thickness in the living eye have recently been extensively reviewed and criticized by von Bahr (1948a), who devised an ingenious method (1948a, b) of overcoming the practical difficulties and theoretical objections of its forerunners. He employed an apparatus consisting of two rotating glass plates, coupled by gearing, which were mounted in front of the...
متن کاملUse of a slit-lamp microscope for treating impacted facial foreign bodies in the emergency department
Identifying, locating, diagnosing, and treating small foreign bodies (FBs) in soft tissues is a challenge for emergency physicians in the emergency department. Additionally, potential complications owing to the remnant FBs are medico-legally significant. The efficacy of conventional imaging methods such as radiography, computed tomography, and ultrasonography are largely limited in visualizing ...
متن کاملComplications: Focus on the Bleb
A 46-year-old myopic white male developed severe hypotony maculopathy with a visual acuity of 8/200 and an IOP of 3 mm Hg 2 weeks after combined phacoemulsification and trabeculectomy with mitomycin C for juvenile glaucoma. Despite success with surgical revision of the bleb in cases of posttrabeculectomy hypotony maculopathy,1-3 we were aware that reopening the conjunctival flap still posed a r...
متن کاملOn focusing the slit-lamp: Part I. An inaccurate ocular setting--what is there to lose?
Adjustments of the diopter rings on the slit-lamp oculars compensate for three independent factors: the observer's refractive error, the observer's state of accommodation, and any instrument misalignment. An inaccurate setting of these rings will significantly affect the slit-lamp image quality, as well as the precision and accuracy of slit-lamp mounted lasers, such as are used for retinal phot...
متن کامل