Separator characteristics for increasing performance of microbial fuel cells.

نویسندگان

  • Xiaoyuan Zhang
  • Shaoan Cheng
  • Xin Wang
  • Xia Huang
  • Bruce E Logan
چکیده

Two challenges for improving the performance of air cathode, single-chamber microbial fuel cells (MFCs) include increasing Coulombic efficiency (CE) and decreasing internal resistance. Nonbiodegradable glass fiber separators between the two electrodes were shown to increase power and CE, compared to cloth separators (J-cloth) that were degraded over time. MFC tests were conducted using glass fiber mats with thicknesses of 1.0 mm (GF1) or 0.4 mm (GF0.4), a cation exchange membrane (CEM), and a J-cloth (JC), using reactors with different configurations. Higher power densities were obtained with either GF1 (46 +/- 4 W/m(3)) or JC (46 +/- 1 W/m(3)) in MFCs with a 2 cm electrode spacing, when the separator was placed against the cathode (S-configuration), rather than MFCs with GF0.4 (36 +/- 1 W/m(3)) or CEM (14 +/- 1 W/m(3)). Power was increased to 70 +/- 2 W/m(3) by placing the electrodes on either side of the GF1 separator (single separator electrode assembly, SSEA) and further to 150 +/- 6 W/m(3) using two sets of electrodes spaced 2 cm apart (double separator electrode assembly, DSEA). Reducing the DSEA electrode spacing to 0.3 cm increased power to 696 +/- 26 W/m(3) as a result of a decrease in the ohmic resistance from 5.9 to 2.2 Omega. The main advantages of a GF1 separator compared to JC were an improvement in the CE from 40% to 81% (S-configuration), compared to only 20-40% for JC under similar conditions, and the fact that GF1 was not biodegradable. The high CE for the GF1 separator was attributed to a low oxygen mass transfer coefficient (k(O) = 5.0 x 10(-5) cm/s). The GF1 and JC materials differed in the amount of biomass that accumulated on the separator and its biodegradability, which affected long-term power production and oxygen transport. These results show that materials and mass transfer properties of separators are important factors for improving power densities, CE, and long-term performance of MFCs.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Polymer separators for high-power, high-efficiency microbial fuel cells.

Microbial fuel cells (MFCs) with hydrophilic poly(vinyl alcohol) (PVA) separators showed higher Coulombic efficiencies (94%) and power densities (1220 mW m(-2)) than cells with porous glass fiber separators or reactors without a separator after 32 days of operation. These remarkable increases in both the coublomic efficiency and the power production of the microbial fuel cells were made possibl...

متن کامل

Electrochemical Impedance Spectroscopy for Investigation of Different Losses in 4-cells Short Stack with Integrated Humidifier and Water Separator

Electrochemical impedance spectroscopy (EIS) is a suitable and powerful diagnostic testing method for fuel cells (FCs) since it is non-destructive and provides useful information about FC performance and its components. In this study, for the first time, a 500W cascade type 4 cells stack with integrated humidifier, water separator and internal manifolds was designed, fabricated and tested. The ...

متن کامل

Spray-on polyvinyl alcohol separators and impact on power production in air-cathode microbial fuel cells with different solution conductivities.

Separators are used to protect cathodes from biofouling and to avoid electrode short-circuiting, but they can adversely affect microbial fuel cell (MFC) performance. A spray method was used to apply a polyvinyl alcohol (PVA) separator to the cathode. Power densities were unaffected by the PVA separator (339±29mW/m(2)), compared to a control lacking a separator in a low conductivity solution (1m...

متن کامل

Using a glass fiber separator in a single-chamber air-cathode microbial fuel cell shortens start-up time and improves anode performance at ambient and mesophilic temperatures.

A shorter start-up time and highly negative anode potentials are needed to improve single-chamber air-cathode microbial fuel cells (MFCs). Using a glass fiber separator reduced the start-up time from 10d to 8d at 20°C, and from 4d to 2d at 30°C, and enhanced coulombic efficiency (CE) from <60% to 89% (20°C) and 87% (30°C). Separators also reduced anode potentials by 20-190mV, charge transfer re...

متن کامل

Application of dual chamber microbial fuel cell with aeration cathode for bioelectricity generation and simultaneous industrial wastewater treatment

Background and Objective: Microbial fuel cell (MFC) is a new green technology that uses the catabolic ability of microorganisms to produce bioenergy while simultaneously removing organic matter and other wastewater contaminants. Electrode material is one of the factors affecting the performance of microbial fuel cells. The aim of this study was to investigate the performance of microbial fuel c...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Environmental science & technology

دوره 43 21  شماره 

صفحات  -

تاریخ انتشار 2009