Establishment of the practical peak voltage for standard computed tomography radiation qualities at a Calibration Laboratory

نویسندگان

  • Vitor Vivolo
  • Lucio P. Neves
  • Ana P. Perini
  • Linda V. E. Caldas
چکیده

At the Calibration Laboratory of IPEN/CNEN-SP (LCI) several radiation qualities were established, and they are in use for the calibration of radiation detectors for clinical and industrial uses. In order to follow international recommendations, a new quantity has been established at the LCI, the practical peak voltage (PPV). In this work, an analysis of this quantity was made for the computed tomography standard radiation qualities RQT8 and RQT9. The PPV and the mean and peak kilovoltage values were measured with a noninvasive Radcal Accu-kV Diagnostic Sensor, model 40X12-W meter. In order to compare the results obtained for PPV a Physikalisch-Technische Werkstätten (PTW) meter, model Diavolt, was also utilized. The tests were performed with an X-ray system Pantak/Seifert, tube model MXR-160/22 (constant potential). The measurements were taken varying the distance between the focal spot and the meters. The uncertainties attributed to the quantities of kV and PPV for a noninvasive method did not exceed 5%, and therefore they were within the IAEA recommendations. In the corresponding measurements, increasing the distance between the focal spot and the meter, the PPV and the kV values should be constant. The results were within the predictions, and the PPV and the kV values presented variations within international recommendations. This type of quality control procedure is very important to verify the good reliability of the X-ray system of LCI, because it is utilized for routine calibration of dosimeters.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of air kerma-length product measurements between the PTB and the IAEA for x-radiation qualities used in computed tomography (EURAMET.RI(I)-S12, EURAMET project #1327)

A comparison of air kerma-length product determinations for standard radiation qualities defined for use in computed tomography (CT) was performed between the PTB and the IAEA as EURAMET project #1327, registered in the KCDB as the EURAMET.RI(I)-S12 comparison. A pencil type reference-class ionization chamber of the IAEA and the three RQT beam qualities established according to the IEC standard...

متن کامل

Development of an Advanced Optical Coherence Tomography System for Radiation Dosimetry

Introduction: According to the literature, optical coherence tomography (OCT) can be used measure radiation absorbed dose. This study was carried out to design a computed tomography system for the calculation of absorbed dose and optimization of dose delivery in radiotherapy using gel dosimeters. Material and Methods: An advanced charge-coupled device based OCT system was developed in laborator...

متن کامل

Dose Assessment in Computed Tomography Examination and Establishment of Local Diagnostic Reference Levels in Mazandaran, Iran

Background: Medical X-rays are the largest man-made source of public exposure to ionizing radiation. While the benefits of Computed Tomography (CT) are well known in accurate diagnosis, those benefits are not risk-free. CT is a device with higher patient dose in comparison with other conventional radiation procedures. Objective: This study is aimed at evaluating radiation dose to patients from ...

متن کامل

Establishment of Diagnostic Reference Levels and Estimation of Effective Dose from Computed Tomography Head Scans at a Tertiary Hospital in South Africa

Introduction: Head scans are the most frequently performed computed tomography (CT) examinations worldwide. However, there is growing concern over the probability of increased cancer risks among the exposed populations. Diagnostic reference levels (DRLs) identify radiation dose that is not commensurate with clinical objectives. The aim of this study was to establish DR...

متن کامل

Optimization of Radiation Dose in Cranial Computed Tomography among Adults: Assessment of Radiation Dose against Image Quality

Introduction: The rapid use of computed tomography (CT) scan is of great concern, due to increase in patients’ dose. Optimization of CT protocol is a vital issue in dose reduction. This study aimed to optimize radiation dose in cranial CT and assess modifications in image quality under radiation dose reduction. Material and Methods: A poly(me...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2012