Medium-term Outcomes of Cemented Prostheses and Cementless Modular Prostheses in Revision Total Hip Arthroplasty
نویسندگان
چکیده
There is an increasing trend towards cementless modular femoral prostheses for revision hip replacement surgery, especially in patients with severe proximal femoral bone defects. However, for minor femoral bone defects, the benefit of cementless modular is not clear. We designed a retrospective cross-sectional study to compare outcomes of the two femoral implant designs. There were no significant differences in terms of visual analog pain scores, Harris hip scores, femoral bone restoration, stem subsidence, leg length correction, or overall complication rate. Three femoral reoperations (11%) occurred in the cemented group, and two (9%) in the cementless modular group. One femoral stem re-revised (4%) in the cemented group due to recurrent deep infection. Five-year survival for femoral reoperation was 88.2% for patients with the cemented implant and 91.3% for cementless group. Both groups had good clinical and radiological outcomes for femoral revision in patients with minor femoral bone defects during medium-term follow-up.
منابع مشابه
Outcomes of Dual Modular Cementless Femoral Stems in Revision Hip Arthroplasty
With an increasing number of primary hip replacements being performed every year, the burden of revision hip arthroplasty, for septic and aseptic loosening, recurrent dislocation or periprosthetic fracture, is also increasing. In recent years, different approaches to revising the femoral prosthesis have emerged; including both cemented and cementless techniques. With a stable cement mantle and ...
متن کاملA modular cementless stem vs. cemented long-stem prostheses in revision surgery of the hip
BACKGROUND AND PURPOSE Modular cementless revision prostheses are being used with increasing frequency. In this paper, we review risk factors for the outcome of the Link MP stem and report implant survival compared to conventional cemented long-stem hip revision arthroplasties. PATIENTS AND METHODS We used data recorded in the Swedish Hip Arthroplasty Register. 812 consecutive revisions with ...
متن کاملFunctional Outcome, Revision Rates and Mortality after Primary Total Hip Replacement – A National Comparison of Nine Prosthesis Brands in England
BACKGROUND The number of prosthesis brands used for hip replacement has increased rapidly, but there is little evidence on their effectiveness. We compared patient-reported outcomes, revision rates, and mortality for the three most frequently used brands within each prosthesis type: cemented (Exeter V40 Contemporary, Exeter V40 Duration and Exeter V40 Elite Plus Ogee), cementless (Corail Pinnac...
متن کاملCementless Hip Arthroplasty in Southern Iran, Midterm Outcome and Comparison of Two Designs
Background: Cementless hip prosthesis was designed to provide biologic fixation, without the use of cement. The second generation components have shown more reliable bone ingrowths and survival rates. We are reporting a midterm result of two designs of cementless prosthesis in a unique culture with different social habits and expectations.Methods: 52 primary cementless total hip arthroplasty in...
متن کاملAggressive granulomatous lesions in cementless total hip arthroplasty.
We describe six patients with aggressive granulomatous lesions around cementless total hip prostheses. Two patients previously had a cemented prosthesis in the same hip. The Lord prosthesis was used in five patients, the PCA in one. Both prostheses were made of chrome-cobalt alloy. Pain on weight-bearing occurred on average 3.2 years after the cementless arthroplasty, and at that time radiograp...
متن کامل