Clinical utility of the PFA-100.

نویسنده

  • Emmanuel J Favaloro
چکیده

The PFA-100 (platelet function analyzer) is a relatively new tool for the investigation of primary hemostasis. This article reviews the history of the PFA-100 and details its clinical utility in several settings. The PFA-100 was first introduced to us in 1995 in an issue of Seminars in Thrombosis And Hemostasis, which included data from a field trial headed by Dr. Eberhard Mammen. Since that time, the PFA-100 has featured in nearly 500 publications and some 35 reviews. The PFA-100 has potential utility in monitoring antiplatelet therapy (including aspirin) and as a screening tool for investigating possible von Willebrand disease (VWD) and various platelet disorders. The PFA-100 also has potential value for monitoring DDAVP (desmopressin) therapy in both VWD and functional platelet disorders. Most recent attention has focused on sensitivity to antiplatelet medication, where a new language has also emerged, with researchers talking about "aspirin resistance," "aspirin responsiveness," and "aspirin nonresponsiveness." Ultimately, the greatest strengths of the PFA-100 are its simplicity in use and excellent sensitivity to various hemostatic disturbances. However, because it is a "global" test system for primary hemostasis, this also creates a significant limitation because the PFA-100 is not specific for, nor predictive of, any particular disorder. However, used appropriately, the PFA-100 can be considered a worthwhile addition to hemostasis laboratories involved in the identification or therapeutic monitoring of primary hemostatic disorders. The potential future applications for this simple instrument are also briefly assessed.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Diagnostic performance of the platelet function analyzer (PFA-100) for the detection of disorders of primary haemostasis in patients with a bleeding history-a systematic review and meta-analysis.

The Platelet Function Analyzer (PFA-100) is increasingly being used in the workup of patients with a bleeding diathesis. A profound knowledge of the possible diagnostic performance of this test is essential in order to make sound clinical decisions based on its results. It was the aim of this study to systematically review the published literature and provide valid estimates of the diagnostic p...

متن کامل

The Present Situation of Patellofemoral Arthroplasty in the Management of Solitary Patellofemoral Osteoarthritis

Patellofemoral (PF) osteoarthritis (OA) is a somewhat predominant illness, affecting up to 24% of women and 11% ofmen over the age of 55 years who suffer from symptomatic knee OA. The purposes of this narrative overview are tosummarize the present situation of patellofemoral arthroplasty (PFA) in the treatment of solitary PF-OA, and to givean account of the clinical results of...

متن کامل

Platelet function analyzer (PFA)-100 closure time in the evaluation of platelet disorders and platelet function: a rebuttal.

BACKGROUND Closure time (CT), measured by platelet function analyzer (PFA-100) device, is now available to the clinical laboratory as a possible alternative or supplement to the bleeding time test. AIM On behalf of the Platelet Physiology Subcommittee of the Scientific and Standardization Committee of the International Society on Thrombosis and Haemostasis (ISTH-SSC), a working Group was form...

متن کامل

The role of PFA-100 testing in the investigation and management of haemostatic defects in children and adults.

The PFA-100 provides a simple global measure of high shear-dependent platelet function, and as such is not diagnostic or specific to any disorder. Prolonged closure times must be interpreted in conjunction with a full blood count, von Willebrand factor (VWF) screen and other platelet tests. The PFA-100 may also give false negative results with relatively common platelet defects. If clinical sus...

متن کامل

Variables that affect platelet function analyzer-100 (PFA-100) closure times and establishment of reference intervals in Korean adults.

The PFA-100 is an in vitro system for measurement of platelet function in whole blood. To establish reference intervals in the Korean population, we investigated the relationships between PFA-100 closure times and gender, ABO blood group, citrate concentration, and time of blood collection in 120 well-characterized healthy Korean adults. Gender did not affect closure time values. Blood group O ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Seminars in thrombosis and hemostasis

دوره 34 8  شماره 

صفحات  -

تاریخ انتشار 2008