Inner volume BOLD-fMRI at ultra-high spatial resolution
نویسندگان
چکیده
Introduction: Multi-Echo FLASH imaging in combination with echo train shifting [1,2] offers BOLD sensitivity for matrix sizes up to 256 x 256 leading to in-plane resolutions of about 1 mm. Long measurement times and low Signal-to-Noise-Ratio (SNR) preclude BOLDfMRI going to higher resolutions. Hence, only a reduction in the Field-of-View (FOV) further increases spatial resolution. Latter, however, is limited by aliasing artifacts due to signals from outside of the FOV. 2D-selective excitation [3] in sliceand phase encoding direction, as shown in Fig. 1, allows for small inner FOV sizes resulting in increased spatial resolution. Recently, applications with two-dimensional pulse profiles such as spiral [4] or blipped planar [5] excitation trajectories were reported. In this study, latter one was chosen because the limiting side excitations only occur in one single dimension.
منابع مشابه
Ultra high-field (7 T) multi-resolution fMRI data for orientation decoding in visual cortex
Multivariate pattern classification methods have been successfully applied to decode orientation of visual grating stimuli from BOLD fMRI activity recorded in human visual cortex (Kamitani and Tong, 2005; Haynes and Rees, 2005) [12], [10]. Though there has been extensive research investigating the true spatial scale of the orientation specific signals (Op de Beeck, 2010; Swisher et al., 2010; A...
متن کاملEffect of Phase-Encoding Reduction on Geometric Distortion and BOLD Signal Changes in fMRI
Introduction Echo-planar imaging (EPI) is a group of fast data acquisition methods commonly used in fMRI studies. It acquires multiple image lines in k-space after a single excitation, which leads to a very short scan time. A well-known problem with EPI is that it is more sensitive to distortions due to the used encoding scheme. Source of distortion is inhomogeneity in the static B0 field that ...
متن کاملSub-millimeter T2 weighted fMRI at 7 T: comparison of 3D-GRASE and 2D SE-EPI
Functional magnetic resonance imaging (fMRI) allows studying human brain function non-invasively up to the spatial resolution of cortical columns and layers. Most fMRI acquisitions rely on the blood oxygenation level dependent (BOLD) contrast employing T(*) 2 weighted 2D multi-slice echo-planar imaging (EPI). At ultra-high magnetic field (i.e., 7 T and above), it has been shown experimentally a...
متن کاملThe effect of acquisition resolution on orientation decoding from V1 BOLD fMRI at 7 T
A decade after it was shown that the orientation of visual grating stimuli can be decoded from human visual cortex activity by means of multivariate pattern classification of BOLD fMRI data, numerous studies have investigated which aspects of neuronal activity are reflected in BOLD response patterns and are accessible for decoding. However, it remains inconclusive what the effect of acquisition...
متن کاملLayer-specific BOLD activation in awake monkey V1 revealed by ultra-high spatial resolution functional magnetic resonance imaging
The laminar structure of the cortex has previously been explored both in non-human primates and human subjects using high-resolution functional magnetic resonance imaging (fMRI). However, whether the spatial specificity of the blood-oxygenation-level-dependent (BOLD) fMRI is sufficiently high to reveal lamina specific organization in the cortex reliably is still unclear. In this study we demons...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -
تاریخ انتشار 2008