A transatrial pericardial access: lead placement as proof of concept.

نویسندگان

  • G S Kassab
  • M Svendsen
  • W Combs
  • J S Choy
  • E J Berbari
  • J A Navia
چکیده

A safe, easy, and quick access into the pericardial space may provide a window for diagnostics and therapeutics to the heart. The objective of this study was to provide proof of concept for an engagement and access catheter that allows access to the pericardial space percutaneously. A multilumen catheter was developed to allow navigation and suction fixation to the right atrial appendage/wall in a normal swine model. Advancement through the multilumen catheter using a second catheter with a distal needle tip allows access to the pericardial space without pericardial puncture and advancement of a standard guide wire into the space. Navigation into the pericardial space was undertaken by fluoroscopy alone and was accomplished in 10 swine (5 acute and 5 chronic). As a specific application of this pericardial access method, a pacing lead was implanted on the epicardial surface. Five chronic swine experiments were conducted with successful pacing engagement verified by lead impedance and pacing threshold and sensing. Lead impedance exceeded 1,000 Omega preengagement and dropped by an average of 200 Omega upon implant (769 +/- 498 Omega). Pacing thresholds at 0.4 ms ranged from approximately 0.5 to 2.1 V acutely (1.03 +/- 0.92 V). No cardiac effusion or tamponade was observed in any of the acute or chronic studies. The ability to engage, maintain, and retract the right atrial appendage/wall and to engage an epicardial lead was successfully demonstrated. These findings support the feasibility of safe access into the pericardial space in a normal swine model and warrant further investigations for clinical translation.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Transatrial access to the normal pericardial space: a novel approach for diagnostic sampling, pericardiocentesis, and therapeutic interventions.

BACKGROUND A nonsurgical means to access the normal pericardial space could provide opportunities for diagnostic sampling and therapeutic interventions. Because there are currently no approved nonsurgical methods to accomplish this, we tested a new approach in large animals. METHODS AND RESULTS A catheter system was employed in a percutaneous approach from a femoral vein to pierce the right a...

متن کامل

Percutaneous transatrial access to the pericardial space for epicardial mapping and ablation.

BACKGROUND Puncture of the atrial appendage may provide access to the pericardial space. The aim of this study was to evaluate the feasibility of epicardial mapping and ablation through an endocardial transatrial access in a swine model. METHODS AND RESULTS An 8-F Mullins sheath was used to perforate the right (n=16) or left (n=1) atrial appendage in 17 pigs (median weight, 27.5 kg; first and...

متن کامل

Persistent primary coronary dilation induced by transatrial delivery of nitroglycerin into the pericardial space: a novel approach for local cardiac drug delivery.

OBJECTIVES We compared the effects of intrapericardial and intracoronary nitroglycerin on coronary cross-sectional area as assessed by intravascular ultrasound and demonstrated the feasibility of local cardiac drug delivery by a newly developed method to access the normal pericardial space through the right atrial appendage. BACKGROUND Studies of nitric oxide (NO) donors have suggested that t...

متن کامل

Real-time cardiovascular magnetic resonance subxiphoid pericardial access and pericardiocentesis using off-the-shelf devices in swine

BACKGROUND Needle access or drainage of pericardial effusion, especially when small, entails risk of bystander tissue injury or operator uncertainty about proposed trajectories. Cardiovascular magnetic resonance (CMR) might allow enhanced imaging guidance. METHODS AND RESULTS We used real-time CMR to guide subxiphoid pericardial access in naïve swine using commercial 18G titanium puncture nee...

متن کامل

Pacemaker implantation through pericardial reflections under fluoroscopic guidance: a novel approach for patients with limited venous access

Methods Between June 2006 and November 2011, 15 adult patients underwent epimyocardial atrioventricular pacemaker implantation through a minimally invasive subxiphoid approach and pericardial window. Mean age was 46.4 ± 15.3 years and 9 (60.0%) patients were male. Patients selected for this new surgical approach were not amenable to transvenous lead placement due to: multiple abandoned leads (5...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • American journal of physiology. Heart and circulatory physiology

دوره 298 1  شماره 

صفحات  -

تاریخ انتشار 2010