The MOnitoring Resynchronization dEvices and CARdiac patiEnts (MORE-CARE) Randomized Controlled Trial: Phase 1 Results on Dynamics of Early Intervention With Remote Monitoring

نویسندگان

  • David Smithard
  • Dieter Hayn
  • Guenter Schreier
  • Giuseppe Boriani
  • Antoine Da Costa
  • Renato Pietro Ricci
  • Aurelio Quesada
  • Stefano Favale
  • Saverio Iacopino
  • Francesco Romeo
  • Arnaldo Risi
  • Lorenza Mangoni di S Stefano
  • Xavier Navarro
  • Mauro Biffi
  • Massimo Santini
  • Haran Burri
چکیده

BACKGROUND Remote monitoring (RM) in patients with advanced heart failure and cardiac resynchronization therapy defibrillators (CRT-D) may reduce delays in clinical decisions by transmitting automatic alerts. However, this strategy has never been tested specifically in this patient population, with alerts for lung fluid overload, and in a European setting. OBJECTIVE The main objective of Phase 1 (presented here) is to evaluate if RM strategy is able to reduce time from device-detected events to clinical decisions. METHODS In this multicenter randomized controlled trial, patients with moderate to severe heart failure implanted with CRT-D devices were randomized to a Remote group (with remote follow-up and wireless automatic alerts) or to a Control group (with standard follow-up without alerts). The primary endpoint of Phase 1 was the delay between an alert event and clinical decisions related to the event in the first 154 enrolled patients followed for 1 year. RESULTS The median delay from device-detected events to clinical decisions was considerably shorter in the Remote group compared to the Control group: 2 (25(th)-75(th) percentile, 1-4) days vs 29 (25(th)-75(th) percentile, 3-51) days respectively, P=.004. In-hospital visits were reduced in the Remote group (2.0 visits/patient/year vs 3.2 visits/patient/year in the Control group, 37.5% relative reduction, P<.001). Automatic alerts were successfully transmitted in 93% of events occurring outside the hospital in the Remote group. The annual rate of all-cause hospitalizations per patient did not differ between the two groups (P=.65). CONCLUSIONS RM in CRT-D patients with advanced heart failure allows physicians to promptly react to clinically relevant automatic alerts and significantly reduces the burden of in-hospital visits. TRIAL REGISTRATION Clinicaltrials.gov NCT00885677; http://clinicaltrials.gov/show/NCT00885677 (Archived by WebCite at http://www.webcitation.org/6IkcCJ7NF).

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Telemonitoring of Patients with Implantable Cardiac Devices to Manage Heart Failure: An Evaluation of Tablet-PC-Based Nursing Intervention Program

Background: With the rapid aging of society, the number of patients with heart failure has also increased. Implantable devices for heart failure have become standardized. Remote monitoring using cardiac devices has grown in popularity for medical efficiency and the early detection of abnormalities. Our first aim was to develop a tablet-PC-based nursing intervention program for patients requirin...

متن کامل

Technical reliability and clinical safety of a remote monitoring system for antiarrhythmic cardiac devices.

INTRODUCTION AND OBJECTIVES In recent years, physicians have experienced a huge increase in workload associated with cardiac devices. Remote monitoring enables these devices to be monitored at a distance and could reduce the number of hospital visits. The aim of this study was to assess the technical reliability and clinical safety of the Home MonitoringTM remote monitoring system (Biotronik Gm...

متن کامل

Remote Monitoring of Cardiac Implantable Electronic Devices

Pacemakers, implantable cardioverter-defibrillators, and cardiac resynchronization devices use advanced diagnostic functions to continuously monitor the patient and the device itself. Follow-up is necessary after implantation to provide individualized treatment and to detect malfunctions. Routine office visits, however, do not provide access to these data on a timely basis. Transtelephonic pace...

متن کامل

تأثیر مداخله آموزشی مبتنی بر الگوی مراقبت پیگیر بر خودپایشی قند خون بیماران دیابتی نوع 2

Background and Aim: Appropriate control of blood sugar delays the onset and progression of diabetes mellitus (DM) complications. Nurses have a decisive role in the education of self-care behaviors to diabetic patients, including self-monitoring of blood glucose. The current study aimed at assessing the effect of educational intervention based on continuous care model on self-monitoring of blood...

متن کامل

Randomized trial of atrial arrhythmia monitoring to guide anticoagulation in patients with implanted defibrillator and cardiac resynchronization devices.

AIMS Atrial tachyarrhythmias (ATs) detected by implanted devices are often atrial fibrillation or flutter (AF) associated with stroke. We hypothesized that introduction and termination of anticoagulation based upon AT monitoring would reduce both stroke and bleeding. METHODS AND RESULTS We randomized 2718 patients with dual-chamber and biventricular defibrillators to start and stop anticoagul...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 15  شماره 

صفحات  -

تاریخ انتشار 2013