Reproducibility and validity of the DynaPort KneeTest.

نویسندگان

  • Lidwine B Mokkink
  • Caroline B Terwee
  • Rienk M A van der Slikke
  • Rob C van Lummel
  • Rob J Benink
  • Lex M Bouter
  • Henrica C W de Vet
چکیده

OBJECTIVE To determine the reproducibility and validity of the DynaPort KneeTest, a performance-based test that measures quality of movement of patients undergoing total knee replacement (TKR). METHODS A total of 92 patients with osteoarthritis (OA) of the knee performed the KneeTest twice on the same day; 94 healthy controls performed the KneeTest once. During the test, 29 activities were performed with accelerometers attached to the body. Relevant functional parameters were extracted from the accelerometers. A selection of parameters was used to calculate activity scores, based on the ability of parameters to discriminate between patients and controls (regression analyses). Based on internal consistency analyses (Cronbach's alpha), redundant activities were removed. Four cluster scores and a total KneeScore were calculated from the remaining activity scores. Reproducibility and validity of the cluster scores and the total KneeScore 2 were assessed. RESULTS Based on internal consistency analyses, the test was reduced to 23 activities. Inter- and intraobserver reliability using intraclass correlation coefficients were 0.90 (0.83-0.94) and 0.95 (0.83-0.98), respectively. Limits of inter- and intraobserver agreement were -8.3 to 11.3 and -4.2 to 9.0. Construct validity was confirmed by expected correlations with the Western Ontario and McMaster University Osteoarthritis Index physical functioning (0.55), Medical Outcomes Study Short Form-36 Health Survey physical functioning (0.62), and Knee Society Score function (0.64). CONCLUSION The KneeTest is a useful performance-based measure for research in patients with knee OA undergoing TKR, with good reliability and validity. Further research is required to improve its usefulness for clinical practice.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Self-reported physical functioning was more influenced by pain than performance-based physical functioning in knee-osteoarthritis patients.

BACKGROUND AND OBJECTIVES To test the hypothesis that self-reported physical functioning is more influenced by pain than performance-based physical functioning. METHODS 163 knee-osteoarthritis patients completed the performance-based DynaPort KneeTest (DPKT), Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC), and SF-36 (self-report measures of pain and physical functionin...

متن کامل

Reproducibility of a triaxial seismic accelerometer (DynaPort).

PURPOSE To examine the reproducibility of a triaxial seismic accelerometer under controlled conditions and real-life conditions. METHODS Instrumental reproducibility was examined using a shaker device. The accelerometers (DynaPort MiniMod; McRoberts B.V., The Hague, The Netherlands) were shaken at four frequencies (0.8, 2.1, 3.6, and 4.6 Hz) in x- and y-directions. The magnitude of accelerati...

متن کامل

Validity of DynaPort GaitMonitor for assessment of spatiotemporal parameters in amputee gait.

Accelerometry can be used to objectively assess the walking ability of people with a lower-limb prosthesis inside and outside the laboratory setting. In this study, the validity of the DynaPort GaitMonitor software (McRoberts, The Hague, the Netherlands) for assessing spatiotemporal parameters of amputee gait was evaluated. Fourteen subjects with a lower-limb prosthesis walked on a straight lev...

متن کامل

Validity and Reliability of Accelerometer-Based Gait Assessment in Patients with Diabetes on Challenging Surfaces

Walking on irregular terrain influences gait of diabetic patients. We investigate the test-retest reliability and construct validity of gait measured with the DynaPort MiniMod under single and dual task conditions in diabetic patients walking on irregular terrain to identify the measurement error (precision) and minimal clinical detectable change. 29 patients with Type 2 diabetes were measured ...

متن کامل

Validity of Six Activity Monitors in Chronic Obstructive Pulmonary Disease: A Comparison with Indirect Calorimetry

Reduced physical activity is an important feature of Chronic Obstructive Pulmonary Disease (COPD). Various activity monitors are available but their validity is poorly established. The aim was to evaluate the validity of six monitors in patients with COPD. We hypothesized triaxial monitors to be more valid compared to uniaxial monitors. Thirty-nine patients (age 68±7 years, FEV(1) 54±18%predict...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Arthritis and rheumatism

دوره 53 3  شماره 

صفحات  -

تاریخ انتشار 2005