Simplified rat intubation using a new oropharyngeal intubation wedge.

نویسندگان

  • I M Jou
  • Y T Tsai
  • C L Tsai
  • M H Wu
  • H Y Chang
  • N S Wang
چکیده

Our new oropharyngeal intubation wedge made from a plastic 3-ml syringe has been used successfully for the expansion of the oropharyngeal cavity and visualization of vocal cords for endotracheal intubation in the rat. All the animals we used tolerated the intubation and ventilation procedures in a series of experiments. After the proper setting of the respirator, vital signs were maintained within normal range. The postmortem examination and measurements in the upper airway confirmed that the endotracheal tube was properly sited and also demonstrated the precise size of the device that should be used. The main advantages of this method include low cost, simplicity, and reliability. Furthermore, because no expensive, elaborate, difficult-to-operate, or hard-to-get special equipment is needed, this technique can be used in every laboratory.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A case of unexpectedly difficult intubation caused by a large asymptomatic choanal polyp

We report a case of unexpectedly difficult intubation in a patient with a huge but asymptomatic choanal polyp. A 77-year-old man with invasive bladder cancer was scheduled for total cystectomy under general anesthesia. However, tracheal intubation with a Macintosh laryngoscope proved impossible due to obstruction by a large oropharyngeal tumor. Using a video laryngoscope, intubation was success...

متن کامل

Fibreoptic awake intubation--a method of topical anaesthesia and orotracheal intubation.

Three cases of trismus caused by oropharyngeal sepsis are described where fibreoptic-assisted awake intubation using an oral airway intubator and nebulised lidocaine was safely and successfully achieved.

متن کامل

Preoperative airway assessment: predictive value of a multivariate risk index.

Using readily available and objective airway risk criteria, a multivariate model for stratifying risk of difficult endotracheal intubation was developed and its accuracy compared to currently applied clinical methods. We studied 10,507 consecutive patients who were prospectively assessed prior to general anesthesia with respect to mouth opening, thyromental distance, oropharyngeal (Mallampati) ...

متن کامل

Awake video laryngoscope intubation: case report of a patient with a nasopharyngeal mass.

Difficult airway management remains central to anesthesia practice. Video laryngoscopes have been an adjunct to airway management since the early 2000s. They have been shown to improve visualization of the glottic opening and have become a useful aid in managing difficult airways. To date, the preferred method for difficult airway management remains awake fiberoptic intubation. The purpose of t...

متن کامل

Successful intubation using retrograde trans-tracheal illumination after laryngoscope light source failure.

Properly functioning equipment is critical during direct laryngoscopy for endotracheal intubation. When the light source on a laryngoscope fails, proper visualization of the glottic opening is then extremely difficult in the then dark vault of the oropharynx, and alternative endotracheal intubation techniques must often be employed in a time sensitive manor. Laryngoscopic light source failure m...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of applied physiology

دوره 89 5  شماره 

صفحات  -

تاریخ انتشار 2000