Commentary: Flow-injection analysis—an idea incomplete?
نویسنده
چکیده
The ultimate aim of any instrumentation must be 'sample in-result out in 1-2 min.'. This specification has been the reason for the phenomenal success of flame analysis, it is the reason for the now remarkable success of the near infra-red analysis for protein, fat etc. and for the continuing research after more than 60 years into all methods of electrode measurements. Yet Flow-Injection Analysis (FIA) which has often been publicized in the same terms, has still to make a significant impact in the analytical laboratory if by 'impact' we mean systems sold in comparison with the number of Technicon AutoAnalyzers or similar continuous flow systems. A conservative estimate suggests that more than 50 000 continuous flow units are now in the field after about 25 years. A fully automated FIA-type system was, after all, commercially available in 1959 and described in great detail by Jonnard [1] for the analysis of chromate, protein, urinary glucose, red blood cells and haemoglobin. The fundamental theory of FIA, that is the dispersion of a sample slug in a flowing stream, was first developed by Taylor [2] in 1953 and subsequently by Aris [3] in 1956. The concept was reintroduced into electro-chemistry by Pungor's school in 1970 and, since 1976, widely expanded by Ruzicka and his colleagues in the academic press. Today at least four firms market FIA systems actively in Europe and the USA. Hence the very limited acceptance of FIA by practising analysts cannot be blamed on a lack of history, academic support or commercial exploiters. The goal ofFIA is certainly achievable-theoretically. Given completely turbulent flow (Reynold's number greater than 1000), a sample injected into such a stream would be recorded as a complete square wave on any detector. Samples can be injected at hundreds/h, each peak could be monitored for quality of the assay and so duplicates would be unnecessary. Micro samples could be used with high precision and if the reactions were relatively simple, increased reaction rates would often be possible using high temperatures with the high pressures necessary. Separations using packed columns would open new possibilities without significant loss of the square wave. The price? A high/very-high pressure system of narrow bore tubes (0.2 ram?) with velocities in the order of 500cm/s and possible (but not certainly) high reagent consumption. To my knowledge, the obvious technological problems have never been solved on a commercial instrument. In contrast, .FIA uses conventional …
منابع مشابه
Comment: Comments on ‘Flow-injection analysis— an idea incomplete?’
it has required the perception of workers such as Rfi.i6ka and Hansen [6] and Stewart et al. I-7] for the realization that this apparently simple operation was capable ofa remarkable degree of exploitation. It was, in fact, the prolific work of Rfl2i6ka and Hansen [1 and 2] that led us to investigate the potential of FIA in clinical chemistry. Using simple systems constructed from items ofequip...
متن کاملUltra-trace Determination of Palladium(II) by Spectrophotometric Flow Injection Analysis
Nowadays, palladium compounds due to their especial characteristics used in different industries, mainly in electrical power sources and chemical productions as a catalyst. Therefore, Pd concentration is increasing in our around that can be contaminant our environment due its toxic effects. In this work, a simple, selective and rapid flow injection method of analysis (FIA) has been developed fo...
متن کاملAnalysis of air injection system for drag reduction in high speed vessels using numerical simulation software ANSYS-Fluid Flow
Many existing phenomena in nature are considered new design ideas in various fields of industry. Bionics is the application of biological methods and systems found in nature to the study and design of engineering systems and modern technology. By performing bionic review, the researchers found the penguins by delivering air locked under their wings and creating air bubbles, the drag significant...
متن کاملModeling and Analysis of Viscous Dissipation Phenomenon on Temperature Distribution in the Process of Injection Explosive Fluid
The explosive viscous liquid becomes inject to warhead by discharge system. The injection device is consisted of a piston to move down and leads the viscous fluid through the cylindrical pipe towards the end of the duct. Then the viscous fluid leads into a convergent path that will be injected to the warhead or other injection equipment. In this project, the path of viscous fluid flow is divide...
متن کاملCommentary of Covenant in the Holy Verse: When Allah Made (His) Covenant with the Prophets
Waiting for a savior and a better future has been known as a true and respectable idea of revealed religions. However, little considerable study has been performed on the real meaning of waiting as a Divine promise in the prophets and their followers` minds and lives. On the studies in the field, the problem of waiting as a continuous reality in the history of prophecy may be searched in the ve...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- The Journal of Automatic Chemistry
دوره 4 شماره
صفحات -
تاریخ انتشار 1982