Doses Recorded by Passive Dosimeters in Special Circumstances and the Badge Filter Influence on Dose Ranges

نویسندگان

  • F. MIHAI
  • A. STOCHIOIU
چکیده

The response of the passive photodosimeter with halide film characterized by a high optical density of about 0.550 ± 0.007 was analysed on dose ranges, taking into consideration the filters of the dosimetric badge, and finally compared with the thermoluminescent dosimeter (TLD). In this respect the dosimeters were exposed to a Cs 137 calibration radioactive source at different points within (0.01 – 100) mSv dose range. The photodosimeter badge contains plastic, Al, Cu, and Pb filters and the TLD badge has plastic and Al filters. The lowest standard deviations regarding the film response repeatability from a photodosimeter to others over the (0.1–50) mSv and also, an increasing of optical density in the low dose range (0.1–0.3) mSv were obtained on the window image area. Good results for calculating doses over (0.2–30) mSv dose range on the D10 film under Plastic and Cu 1.00 mSv and over (20–100) mSv on D2 film under Pb 0.40 mm filter were also obtained.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

ارزیابی ضرورت به‌کارگیری دزیمتر فردی در رادیولوژی دندان

Lowness of the registered doses by the personal dosimeters (film badge in Iran) for most of dental radiology practitioners has made some of them doubtful about the rightness of the employed dosimetry method. On the other hand, some relatively considerable occupational exposures in dental radiology have been reported. These two opposite facts propose a comprehensive statistical and analytical re...

متن کامل

A Validation Study on Radiation properties of a Novel LiF: Mg, Ti Known as IAP-100

Introduction: LiF dosimeter has the most application in medicine. This study aimed to evaluate some dosimetric properties of a novel LiF: Mg, Ti. Materials and Methods: An ELEKTA Precise linear accelerator was used to calibrate dosimeters at 6 MV. In this survey, responses of dosimeters were evaluated up to 1000 cGy. Background effect was investigated in two different dosimeter states includin...

متن کامل

Estimate bowtie filter shape in PET/CT scan with TLD

Introduction: The CT machine utilizes a bowtie filter to shape the X-ray beam and remove lower energy photons. Configuration of this bowtie filter is complex and its geometry is often not available in detail. It causes the CT dose index (CTDI) be with the different values in measurement versus Monte Carlo simulation studies and other analytical calculations. It is important esp...

متن کامل

stimate bowtie filter shape in PET/CT scan with TLD

Introduction: The CT machine utilizes a bowtie filter to shape the X-ray beam and remove lower energy photons. Configuration of this bowtie filter is complex and its geometry is often not available in detail. It causes the CT dose index (CTDI) be with the different values in measurement versus Monte Carlo simulation studies and other analytical calculations. It is important esp...

متن کامل

Dosimetric influence of Flattening Filter (FF) and Flattening Filter Free (FFF) 6 and 10 MV photon beams on Volumetric Modulated Arc Therapy (VMAT) planning in case of prostate carcinoma

Background: In the treatment of prostate cancer, radiotherapy is the potential to increase second primary cancers such as bladder and rectal cancers. The reasons for this potential are more monitor units (MUs), therefore a larger total body dose because of leakage radiation, a bigger volume of normal tissue is exposed to lower radiation doses. This study was designed to compare the integral dos...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2014