A Laboratory Perspective for Errors in Potassium Measurement

نویسنده

  • Chethana Chethan
چکیده

Errors in potassium measurement can lead to falsely elevated potassium level that is pseudo hyperkalemia. Usually these errors are recognized either by the clinicians or laboratory personals. The factors which causes pseudo hyperkalemia can mask hypokalemia by pushing low value to normal value, which is very difficult identify by laboratory personals. In this article we are discussing the causes and mechanisms of spuriously elevated potassium.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Evaluation of the total analytical error in the flame photometry method

Background and Objectives: For total analytical error, imprecision (SD) and bias, performance goals for laboratory tests have most often been developed. A total analytical error goal requires that the combination of errors from all sources (random and systematic errors) be within some acceptable limit. M...

متن کامل

Potassium reserves in soils with arid and semi-arid climate in southern Iran: a perspective based on potassium fixation

ABSTRACT- The present research was conducted to study K forms and fixation in soils of southern Iran (Hormozgan Province) with aridic and aridic-ustic regimes and to address the relations between soil mineralogy and potassium forms. Thirteen surface soil samples (0-25 cm) were collected from different regions and analyzed in laboratory. Illite and feldspar and mica are the major clay and soil m...

متن کامل

Qualitative and Quantitative Approaches for Determination of Hemolyzed Serum

Abstract Background and Objective: Prevention of medical laboratory errors is a major goal of quality control programs. Hemolyzed specimen is one of the common issues causing medical laboratory errors. Apart from the visual assessment, the measurement of serum hemoglobin concentration can be another method to evaluate the intensity of hemolysis. We aimed to assess hemolyzed serum s...

متن کامل

ٍEffective factors on the Incidence of medication errors from the nursing staff perspective in various department of Fasa Hospital

 Background and Objective: The incidence of medical errors is deemed one of the unavoidable cases of serious threats to the health and safety of patients. This study aimed to determine the factors influencing medication errors from the perspective of the nursing staff. Materials and Methods: This descriptive -analytic study recruited 80 nurses working in various wards in Fasa Hospital. The nurs...

متن کامل

Performance Comparison of Two Different Branded Blood Collection Tubes Used in Biochemistry Laboratory

Background and Aims: Blood collection tubes (BCT) with gel separators are diagnostic devices that can affect all laboratory processes. In this study, the aim was to compare the performance of a new brand of BCT with the sample tubes that are well-known and widely used in the market. Materials and Methods: Blood samples were taken from 50 healthy volunteers to two brands of BCTs (KWS and BD Vac...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2016