Hyperopic automated lamellar keratoplasty: complications and visual results.
نویسندگان
چکیده
OBJECTIVE To examine the long-term safety and efficacy of hyperopic automated lamellar keratoplasty (H-ALK) for correction of primary hyperopia and for consecutive hyperopia following overcorrected myopic refractive surgery. METHODS A prospective study was done on 67 eyes of 50 consecutive patients who underwent H-ALK between March 17, 1993, and August 18, 1995. Hyperopic automated lamellar keratoplasty was performed for primary hyperopia in 25 eyes (group 1) and for consecutive hyperopia after myopic refractive surgery in 42 eyes (group 2, radial keratotomy, 41 eyes, and myopic automated lamellar keratoplasty, 1 eye). The eyes were followed up for a mean+/-SD of 19.2+/-12.8 months (range, 3-49 months), 58 (87%) of them with 6 months' follow-up, and 45 (67%) of them with at least 1 year's follow-up. Twenty-one eyes were followed up for 2 to 4 years. RESULTS The overall mean+/-SD preoperative spherical equivalent was +2.87+/-1.28 diopters (D). The mean+/-SD postoperative spherical equivalent was -0.03+/-1.42 D at 3 months, -0.42+/-2.25 D at 6 months, -0.55+/-3.00 D at 1 year, -1.58+/-1.53 D at 2 years, and -0.35+/-1.79 D at the last follow-up. A mean myopic shift of 0.50 D was noted between 3 months and 1 year, and of 1.00 D between 1 and 2 years. Hyperopia was meaningfully reduced and visual acuity was improved by H-ALK, especially for patients with primary hyperopia. Long-term refractive instability, however, is a serious problem with this procedure. In this series, 11 (26%) of 42 eyes in which H-ALK was performed for consecutive hyperopia developed iatrogenic keratoconus. CONCLUSION Based on this study, the long-term instability of H-ALK and the high incidence of iatrogenic keratoconus following the procedure should discourage its use, especially for consecutive hyperopia following radial keratotomy.
منابع مشابه
Comparison of two microkeratome systems.
BACKGROUND Microkeratomes are currently used for keratomiluesis in situ (automated lamellar keratoplasty) for myopia and hyperopia and for laser in situ keratomileusis (LASIK). Visual and refractive complications have been reported with these refractive surgical procedures. We compared two microkeratomes in their ability to resect corneal lamellae to gain insight into possible mechanism(s) of r...
متن کاملAutomated lamellar keratoplasty for the correction of hyperopia.
Hyperopic automated lamellar keratoplasty (H-ALK) is a refractive procedure that corrects low to moderate hyperopia of up to +5.00 diopters (D). In this retrospective series, we examined the efficacy, predictability, and safety of H-ALK in 85 eyes in 49 patients. Follow-up was from 4 to 34 weeks (mean 18 weeks). Eyes were divided into three subsets: those in which we attempted an emmetropic res...
متن کاملOne donor cornea for 3 recipients: a new concept for corneal transplantation surgery.
OBJECTIVE To describe the use of a single donor corneal tissue in 3 patients with corneal pathologic conditions. METHODS A donor corneal tissue was divided into 3 parts using a microkeratome and a trephine. The anterior lamellar disc was transplanted into a patient with macular corneal dystrophy using the automated lamellar therapeutic keratoplasty technique. The posterior lamellar disc was t...
متن کاملDeep lamellar keratoplasty using viscoelastic dissection.
We describe a technique for performing deep lamellar keratoplasty using viscoelastic dissection. Deep lamellar dissections of the cornea using viscoelastic substances (sodium hyaluronate) were performed on 4 eyes of 4 patients. One patient with keratoconus and another with corneal scarring underwent lamellar keratoplasty using the technique as the sole procedure for visual rehabilitation. Two p...
متن کاملFemtosecond laser-assisted lamellar keratoplasty.
Lamellar keratoplasty consists of transplanting partial-thickness donor cornea onto a complementary recipient bed. Manual lamellar dissection is technically very difficult, time-consuming, and imprecise. Also, the manually-dissected lamellar interface often has topographical irregularities that may optically degrade the best-corrected visual acuity. The femtosecond clinical laser (IntraLase FS ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Archives of ophthalmology
دوره 116 4 شماره
صفحات -
تاریخ انتشار 1998