Estimating 3D Ventricular Shape From 2D Echocardiography: Feasibility and Effect of Noise

نویسندگان

  • Gabriel Bernardino
  • Constantine Butakoff
  • Marta Nuñez Garcia
  • Sebastian Imre Sarvari
  • Merida Rodriguez-Lopez
  • Fátima Crispi
  • Miguel Ángel González Ballester
  • Mathieu De Craene
  • Bart Bijnens
چکیده

Many cardiac diseases are associated with changes in ventricular shape. However, in daily practice, the heart is mostly assessed by 2D echocardiography only. While 3D techniques are available, they are rarely used. In this paper we analyze to which extent it is possible to obtain the 3D shape of a left ventricle (LV) using measurements from 2D echocardiography. First, we investigate this using synthetic datasets, and afterwards, we illustrate it in clinical 2D echocardiography measurements with corresponding 3D meshes obtained using 3D echocardiography. We demonstrate that standard measurements taken in 2D allow quantifying only the ellipsoidal shape of the ventricle, and that capturing other shape features require either additional geometrical measurements or clinical information related to shape remodelling. We show that noise in the measurements is the primary cause for poor association between the measurements and the LV shape features and that an estimated 10% level of noise on the 2D measurements limits the recoverability of shape. Finally we show that clinical variables relating to the clinical history can substitute the lack of geometric measurements, thus providing alternatives for shape assessment in daily practice.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Three-dimensional printing of intracardiac defects from three-dimensional echocardiographic images: feasibility and relative accuracy.

BACKGROUND With the advent of three-dimensional (3D) printers and high-resolution cardiac imaging, rapid prototype constructions of congenital cardiac defects are now possible. Typically, source images for these models derive from higher resolution, cross-sectional cardiac imaging, such as cardiac magnetic resonance imaging or computed tomography. These imaging methods may involve intravenous c...

متن کامل

Analysis of chronic aortic regurgitation by 2D and 3D echocardiography and cardiac MRI

PURPOSE The study compares the feasibility of the quantitative volumetric and semi-quantitative approach for quantification of chronic aortic regurgitation (AR) using different imaging modalities. METHODS left ventricular (LV) volumes, regurgitant volumes (RVol) and regurgitant fractions (RF) were assessed retrospectively by 2D, 3D echocardiography and cMRI in 55 chronic AR patients. Semi-qua...

متن کامل

A Hybrid Method for Endocardial Contour Extraction of Right Ventricle in 4-Slices from 3D Echocardiography Dataset

This paper presents a hybrid method to extract endocardial contour of the right ventricular (RV) in 4-slices from 3D echocardiography dataset. The overall framework comprises four processing phases. In Phase I, the region of interest (ROI) is identified by estimating the cavity boundary. Speckle noise reduction and contrast enhancement were implemented in Phase II as preprocessing tasks. In Pha...

متن کامل

Estimation of 3D left ventricular deformation from echocardiography

The quantitative estimation of regional cardiac deformation from 3D image sequences has important clinical implications for the assessment of viability in the heart wall. Such estimates have so far been obtained almost exclusively from Magnetic Resonance (MR) images, specifically MR tagging. In this paper we describe a methodology for estimating cardiac deformations from 3D echocardiography (3D...

متن کامل

Cross Section Effects on Convergence-Confinement Method in Multi Stage Tunnel Excavation

Dimensionless coefficient () in convergence confinement method shows the relaxation of stress in the wall of the tunnel at different excavation movements. This factor is considered a constant number in previous studies and tunnel geometric characteristics (such as depth, cross-section shape, radius, soil material, etc.) are not included in its determination; however, ignoring these effects can...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2017