Comparison of radiovisiography and digital volume tomography to direct surgical measurements in the detection of infrabony defects

نویسندگان

  • Preeti S. Raichur
  • Swati B. Setty
  • Srinath L. Thakur
  • Venkatesh G. Naikmasur
چکیده

OBJECTIVES To compare the linear measurements of Radiovisiography (RVG) and Digital volume tomography (DVT) to direct surgical measurements in the detection of periodontal infrabony defects. STUDY DESIGN RVG and DVT images were taken prior to periodontal surgery for 28 infrabony periodontal defects. After defect debridement, direct bony defect measurements were made from the cemento enamel junction (CEJ) to the base of the defect (CEJ-BD) and to the alveolar crest (CEJ-AC) with a periodontal probe. These same measurements were made on the RVG and DVT images and then compared to the direct surgical values. RESULTS DVT correlated strongly with surgical measurements, whereas RVG correlated less favorably (P=0.0109, P=0.0193 respectively).No significant difference for CEJ-AC (P=0.0599) was seen between DVT and surgical measurements; however, there was a significant difference for the distance CEJ-BD (P=0.0105). CONCLUSION DVT technique is significantly more accurate than RVG in the detection of infrabony periodontal defects. Key words:Tomography, volume computed, dental radiovisiography, periodontal diseases.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of cone beam computed tomography and digital radiography in detection of pulpal exposure in external cervical root resorption

Background and Aims: Pulpal exposures originated from the external cervical root resorptions have major effects on the treatment and prognosis. Therefore, the aim of this study was performed to compare the two different imaging systems-digital radiography with PSP (Photostimulable Phosphor) sensor in three horizontal different views and CBCT (cone beam computed tomography) images to assess the ...

متن کامل

بررسی مقایسه‌ای دقت Cone beam CT، رادیوگرافی داخل دهانی و پروب پریودنتال در اندازه‌گیری ضایعات استخوانی پریودنتال

Background and Aims: Cone beam computed tomography (CBCT) produces high-quality data about diagnosis and periodontal treatment. To date, there is not enough research regarding periodontal bone measurement using CBCT. The aim of this study was to compare the accuracy of CBCT in measuring periodontal defects to that of intraoral radiography and probing methods.Materials and Methods: Two-hundred a...

متن کامل

Comparing the Accuracy of Cone Beam Computed Tomography,Digital Intraoral Radiography and Conventional Intraoral Radiography in the Measurement of Periodontal Bone Defects

Background and Aim: Cone beam computed tomography (CBCT) produces high-quality data in periodontal diagnosis and treatment planning. The aim of this study was to compare the accuracy of CBCT with intraoral digital and conventional radiography in the measurement of periodontal bone defects.  Methods and Materials: In this diagnostic research, two hundred and eighteen artificial osseous d...

متن کامل

Comparison of Diagnostic Accuracy of Cone Beam Computed Tomography and Digital Radiography for Detection of Vertical Root Fractures with and without Gutta Percha

  Objective: Diagnosis of vertical root fractures (VRFs) is critical in endodontics which most of the times occurs in endodontically treated teeth with root canal fillings such as gutta percha. Despite Cone Beam Computed Tomography (CBCT) has significantly enhanced image quality compared to digital radiography (DR) which aid the diagnosis, artifacts has remained as a problem in VRF detection . ...

متن کامل

Detection of periodontal bone loss using digital intraoral and cone beam computed tomography images: an in vitro assessment of bony and/or infrabony defects.

OBJECTIVES To explore the diagnostic values of digital intraoral radiography and cone beam CT (CBCT) in the determination of periodontal bone loss, infrabony craters and furcation involvements. METHODS Accuracy assessment of the imaging modalities was conducted through bone level measurements, infrabony crater and furcation involvement classifications. For CBCT, images were obtained at 120 kV...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 4  شماره 

صفحات  -

تاریخ انتشار 2012