Shielded Cable Transfer Impedance Measurements High frequency range 100 MHz–1 GHz

نویسنده

  • B. Démoulin
چکیده

©2011 IEEE Plotting the individual components is shown in Fig. 11. Adding the pulses gives the solution for V 10, t 2 shown in Fig. 12. All of the results of the above examples were validated using the PSPICE circuit analysis computer program. Use of the exact lossless transmission line model in PSPICE for more complicated lossless transmission-line problems is highly recommended [1]. VI. References [1] C.R. Paul, “Transmission Lines in Digital and Analog Electronic Systems: Signal Integrity and Crosstalk,” John Wiley, Hoboken, NJ, 2010.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Common-Mode to Differential-Mode Conver- sion in Shielded Twisted-Pair Cables (Shield-Current-Induced Noise)

Neil Muncy [1] has shown that audio frequency current flowing on the shield of twisted-pair audio wiring will be converted to differential mode voltage by any imbalance in the transfer impedance of the cable. He hypothesized that the effect is magnified by the presence of a drain wire and increases linearly with frequency. Whitlock [2] and others have shown that conversion also occurs with capa...

متن کامل

Circuit Models for Conducted Susceptibility Analyses of Multiconductor Shielded Cables

This paper presents circuit models to analyze the conducted susceptibility of multiconductor shielded cables in frequency domains using Branin’s method, which is referred to as the method of characteristics. These models, which can be used directly in the time and frequency domains, take into account the presence of both the transfer impedance and admittance. The conducted susceptibility is stu...

متن کامل

A Multi-Path Signal Propagation Model for the Power Line Channel in the High Frequency Range

For the use of the mains networks as high speed data path for Internet, voice and data services carrier frequencies within the range from 500 kHz up to 20 MHz must be considered. The development of suitable communication systems and the planning of power line communication networks requires measurement-based models of the transfer characteristics of the mains network in the abovementioned frequ...

متن کامل

Electrical Characterization of Textile Transmission Lines

In this paper, electrical characterization and modeling of conductive textiles are presented. A dedicated measurement setup has been developed to allow reliable connection of the textile samples with the equipment cables. Geometrical fabric structures and fabrication tolerances as well as high frequency properties up to 6 GHz for four types of textiles have been determined. Transmission lines w...

متن کامل

High Frequency Testing to Determine Permittivity and Loss Tangent of Embedded Passive Materials

ing dielectric permittivity and loss tangent of embedded passive materials. The measurements are made in an APC-7 coaxial configuration where the test specimen represents a load terminating an air-filled coaxial transmission line. The method is suitable for testing high dielectric constant (high-k) polymer-composite materials having nominal thickness of 1 μm to 300 μm at frequencies of 100 MHz ...