Transcatheter Aortic Valve Implantation With or Without Preimplantation Balloon Aortic Valvuloplasty: A Systematic Review and Meta‐Analysis

نویسندگان

  • Rodrigo Bagur
  • Chun Shing Kwok
  • Luis Nombela‐Franco
  • Peter F. Ludman
  • Mark A. de Belder
  • Sandro Sponga
  • Mark Gunning
  • James Nolan
  • Pantelis Diamantouros
  • Patrick J. Teefy
  • Bob Kiaii
  • Michael W. A. Chu
  • Mamas A. Mamas
چکیده

BACKGROUND Preimplantation balloon aortic valvuloplasty (BAV) is considered a routine procedure during transcatheter aortic valve implantation (TAVI) to facilitate prosthesis implantation and expansion; however, it has been speculated that fewer embolic events and/or less hemodynamic instability may occur if TAVI is performed without preimplantation BAV. The aim of this study was to systematically review the clinical outcomes associated with TAVI undertaken without preimplantation BAV. METHODS AND RESULTS We conducted a search of Medline and Embase to identify studies that evaluated patients who underwent TAVI with or without preimplantation BAV for predilation. Pooled analysis and random-effects meta-analyses were used to estimate the rate and risk of adverse outcomes. Sixteen studies involving 1395 patients (674 with and 721 without preimplantation BAV) fulfilled the inclusion criteria. Crude device success was achieved in 94% (1311 of 1395), and 30-day all-cause mortality occurred in 6% (72 of 1282) of patients. Meta-analyses evaluating outcomes of strategies with and without preimplantation BAV showed no statistically significant differences in terms of mortality (relative risk [RR] 0.61, 95% CI 0.32-1.14, P=0.12), safety composite end point (RR 0.85, 95% CI 0.62-1.18, P=0.34), moderate to severe paravalvular leaks (RR 0.68, 95% CI 0.23-1.99, P=0.48), need for postdilation (RR 0.86, 95% CI 0.66-1.13, P=0.58), stroke and/or transient ischemic attack (RR 0.72, 95% CI 0.30-1.71, P=0.45), and permanent pacemaker implantation (RR 0.80, 95% CI 0.49-1.30, P=0.37). CONCLUSIONS Our analysis suggests that TAVI procedures with or without preimplantation BAV were associated with similar outcomes for a number of clinically relevant end points. Further studies including a large number of patients are needed to ascertain the impact of TAVI without preimplantation BAV as a standard practice.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Transcatheter Aortic Valve Implantation With or Without Preimplantation Balloon Aortic Valvuloplasty: A Systematic Review and Meta‐Analysis

I n the article by Bagur et al, “Transcatheter Aortic Valve Implantation With or Without Preimplantation Balloon Aortic Valvuloplasty: A Systematic Review and Meta-Analysis,” which published online June 13, 2016, and appeared in the June 2016 issue of the journal (J Am Heart Assoc. 2016;5: e003191 doi: 10.1161/JAHA.115.003191), the footnotes section of Table 1 contained errors. On page 4, the s...

متن کامل

Prior balloon valvuloplasty versus DIRECT transcatheter Aortic Valve Implantation (DIRECTAVI): study protocol for a randomized controlled trial

BACKGROUND Balloon predilatation of the aortic valve has been regarded as an essential step during the transcatheter aortic valve implantation (TAVI) procedure. However, recent evidence has suggested that aortic valvuloplasty may cause complications and that high success rates may be obtained without prior dilatation of the valve. We hypothesize that TAVI performed without predilatation of the ...

متن کامل

Balloon aortic valvuloplasty: review of the evidence and current indications

Balloon aortic valvuloplasty was introduced over two decades ago as an alternative to aortic valve replacement in elderly patients deemed unsuitable for surgery. Due to high early restenosis rates and no effect on longterm mortality, the procedure’s development stalled. However, with recent technological advances, in particular the advent of the transcatheter aortic valve implantation, there ha...

متن کامل

بررسی نتایج پیگیری یک ساله بالون والولوپلاستی تنگی مادرزادی دریچه آئورت در کودکان به مدت 10 سال در بیمارستان قلب شهید رجایی

Abstract Background: Balloon valvuloplasty uses for treatment of aortic stenosis from 20 years ago. Regarding loss of information about results of balloon valvuloplasty of hereditary aortic stenosis, this study was done to determine prognosis and complication of balloon valvuloplasty during last 10 years. Methods: This study was done on existing data of all children with hereditary aortic...

متن کامل

Consecutive Sessions of Rescue Balloon Aortic Valvuloplasty for Critical Aortic Valve Stenosis Followed by Successful Bridging to Trans-Catheter Aortic Valve Implantation.

UNLABELLED Percutaneous balloon aortic valvuloplasty (BAV) was a rare procedure in catheterization laboratories because of its limited prognostic impact. The recent advent of transcatheter aortic valve implantation (TAVI) has led to a resurgence of BAV, opening the way to a new indication as a bridge to TAVI. Herein, we reported an 83-year-old man with critical aortic valve stenosis and pulmona...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 5  شماره 

صفحات  -

تاریخ انتشار 2016