Rate-dependency of functional block in the human His bundle and bundle branch-Purkinje system.
نویسندگان
چکیده
SUMMARY In eleven patients in whom atrial premature stimulation elicited functional block in the conduction system distal to the atrioventricular (A-V) node, the influence of atrial driving rate was studied. Functional conduction disturbances in the left bundle branch-Purkinje system were produced by driving the atria at a rate just above the spontaneous sinus rate and by introducing premature atrial stimuli. In five patients this was associated with block or delay of conduction in the right bundle branch-Purkinje system and in one with block within the His bundle. In these patients it was shown that the ultimate QRS configuration of the premature beat was determined by different conduction delays in the three parts of the bundle branch system. In three patients complete block of impulse conduction could be produced below the level of the His bundle, in one within the His bundle. In these four patients conduction delay of earlier atrial premature beats within the A-V node with resumption of conduction in the more peripheral pathways, gave rise to the phenomenon of the A-V gap. In two patients functional conduction delay in the con-tralateral bundle branch caused pseudo-normalization of a pre-existent complete right bundle branch block pattern, indicating that this pattern may not be caused by complete block, but by delayed conduction in the right bundle branch. In ten of the eleven patients functional block or delay of atrial premature beats in the peripheral conduction system became less pronounced as the driving rate was increased. In nine of these ten the phenomenon disappeared completely at higher rates; in six this occurred with an increase in rate of only 20 beats/min. The A-V gap phenomenon present in four cases at the lowest rate disappeared at higher rates in all four. It was concluded that functional conduction disturbances in the peripheral conduction system are favored by a low basic heart rate and that this rate dependency is caused by a differential influence of heart rate upon the functional properties of the A-V node and of the more peripheral parts of the conduction system. F UNCTIONAL BLOCK in the intraventricular conduction system has been defined by Moe and Mendezl as a condition in which an electrocar-diographic pattern of bundle branch block is intermittent or occasional, and dependent upon the preceding cycle length. It is thought to be caused by the fact that the conduction system is functionally inhomogeneous and that variations in excitabil-ity, conductivity …
منابع مشابه
Effects of alternating cycle lengths on refractoriness of the His-Purkinje system.
The effects of alternating cycle lengths (bigeminal rhythm) on His-Purkinje system refractoriness were studied in 14 patients using His bundle and right bundle recordings. Programmed atrial stimulation at constant cycle length (method I) was scanned using the atrial extrastimulus technique (A2) and compared with an atrial cycle length of identical duration coupled to A2 on alternate beats (meth...
متن کاملDetermination of His-Purkinje refractoriness in man with His bundle pacing.
Consistent His bundle pacing was accomplished in one of 60 consecutive patients. Intracardiac electrophysiologic studies in this patient revealed rapid atrioventricular nodal conduction (AH = 55 msec). While the relative refractory period of the His-Purkinje system as a whole determined by His bundle pacing (using the extrastimulus technique) was identical to that determined by atrial pacing, c...
متن کاملStudies of heart block with His bundle electrograms.
A total of 24 patients with heart block revealed by scalar electrocardiography was studied using the His bundle electrogram. Four groups of disturbed conduction are described which include various types of heart block, partial and complete, at different sites, single and multiple, in the specialized conducting system. These are (i) intra-atrial block with delayed or blocked internodal conductio...
متن کاملNMitral Valve Prolapse in One Hundred Presumably Healthy Young Females
14. Fisch C, Zipes DP, McHenry PL: Rate dependent aberrancy. Circulation 48: 714, 1973 15. Denes P, Wu D, Dhingra RC, Amat-y-Leon F, Wyndham C, Rosen KM: Electrophysiological observations in patients with rate dependent bundle branch block. Circulation 51: 244, 1975 16. Wu D, Denes P, Dhingra R, Rosen KM: Bundle branch block. Demonstration of the incomplete nature of some "complete" bundle bran...
متن کاملHis Bundle electrogram in bundle-branch block.
SUMMARY Because a great majority of patients with chronic complete heart block have bilateral bundle-branch lesions, it becomes important to recognize earlier degrees of bilateral bundle-branch block. The H-V interval in the His bundle electrogram during unilateral bundle-branch block reflects the conduction primarily through the contralateral bundle branch, and thus the His bundle electrogram ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Circulation
دوره 48 3 شماره
صفحات -
تاریخ انتشار 1973