Determination of Beryllium in Various Types of Natural Waters by Electrothermal Atomic Absorption Spectrometry
نویسنده
چکیده
The procedure for the reliable determination of Be in natural waters by ETAAS was elaborated. Various modifiers (EDTA, Ca(NO3)2, Mg(NO3)2, Pd(NO3)2 and the mixture of Pd(NO3)2 and Mg(NO3)2) for the determination of beryllium was examined. The applicability of the selected Mg(NO3)2 as the appropriate and generally used modifier for the determination of Be in the different types of natural waters by ETAAS has been confirmed. The accuracy of the method was verified by analyzing of the certified reference material of drinking water ("Trace Metals in Drinking Water"). The real drinking waters and waste waters with the reference values of Be concentration, spiked tap water, mineral waters and model river water were utilized for the determination of Be. Using Mg(NO3)2 for modification, the detection limit of 0.07 μg L, the quantification limit of 0.22 μg L and characteristic mass of 3.7 pg of Be were obtained. The recovery was in the range 95–111% and (%) RSD value was less than 8%.
منابع مشابه
Determination of Cadmium by Electrothermal Atomic Absorption Spectrometry after its Separation and Preconcentration by Syringe to Syringe Dispersive Liquid Phase Microextraction-Solidified Floating Organic Drop
The application of syringe to syringe dispersive liquid phase microextraction-solidified floating organic drop was extended for the separation and preconcentration of trace amounts of cadmium ions from water and cereal samples. The extracted cadmium was quantified by electrothermal atomic absorption spectrometry. Factors affecting the complex formation as well as microextraction efficiency such...
متن کاملCr (VI)/Cr (III) SPECIATION BY IN SITU ELECTRODEPOSITION ONTO TUBE PRIOR TO ELECTROTHERMAL ATOMIC ABSORPTION SPECTROMETRY
متن کامل
Determination of zinc levels in waters from southeastern Spain by electrothermal atomic absorption spectrometry: relationship with industrial activity.
An efficient method for the determination of nanogram levels of zinc in waters (potable, irrigation, waste and sea waters) is described. Acidified water samples were analyzed by an accurately optimized time/temperature program for electrothermal atomic absorption spectrometry. The samples were previously treated with a matrix modifier consisting of 0.1% Mg(NO3)2 in 0.5 M HNO3 and injected throu...
متن کاملElimination of Chemical and Spectral Interferences in Measurement of Trace Elements in Urine and Blood by Combined Electrodeposition-Electrothermal Atomic Absorption Spectrometry
A combined electrodeposition-ETAAS technique has been applied to the analysis of Pb, Cd, Co, Ni, Cr and Mn in biological samples in order to overcome interferences and to minimize sample pretreatment. It requires minimal sample preparation with the electrolysis process aiding partial decomposition of the organic matrix, adequate for the release and deposition of trace elements. In an initia...
متن کاملUtilization of electrodeposition on a graphite probe modified with palladium in determination of lead by graphite furnace atomic absorption spectrometry in water and environmental samples
In this work a rapid and selective procedure for separation and preconcentration of lead(Pb2+) before determination by electrothermal atomic absorption spectrometry (ETAAS) wasdeveloped. The procedure is based on the electrodeposition on a graphite probe modified withpalladium. The lead was deposited from acetate buffer solution at pH 5.5. Various parameters,such as pH of solutions, deposition ...
متن کامل