The noninvasive mouse ear swelling assay. II. Testing the contact sensitizing potency of fragrances.

نویسندگان

  • P S Thorne
  • C Hawk
  • S D Kaliszewski
  • P D Guiney
چکیده

The noninvasive mouse ear swelling assay (MESA) for contact allergy testing was evaluated using fragrance components and complex fragrance mixtures. The test materials represented weak sensitizers and nonsensitizers. Two versions of the MESA were investigated. Both were noninvasive and utilized only topical abdominal dosing and ear challenge with single applications in BALB/cBy mice. The vit A MESA differed from the regular MESA only in that mice were maintained on a diet with 17-fold higher levels of vitamin A (vit A) acetate beginning 3 weeks prior to induction. Sensitization reactions were determined by measuring the mean increase in ear swelling over baseline at 24, 48 and 72 hr postexposure. Irritation dose-response curves facilitated choosing a high nonirritating challenge dose. Sensitization dose-response curves were developed for cinnamaldehyde (CINN) and a complex fragrance mixture, F-16. From these curves, the SD50 was determined. This value represents the dose which sensitized half the animals and serves to rank the potency of compounds for allergic contact dermatitis and to compare values among different assays. The SD50 for CINN was 21.6% while the SD50vit A for F-16 was 26.6%. The other fragrance, isoeugenol (ISOE), and fragrance mixtures, F-07 and F-22, were also found to be weak sensitizers in the MESA and vit A MESA. The results in the MESA for CINN and ISOE were in the range observed with guinea pig test protocols but showed that the MESA was more sensitive than human test protocols. Two of the fragrance mixtures tested in the MESA gave comparable results in the Buehler guinea pig assay. However, the third (F-22) was negative in the Buehler assay and the MESA, but positive in the vit A MESA. The results of this work with weak sensitizers and the companion study (Thorne et al., 1991) with potent sensitizers at low doses illustrate that the noninvasive MESA is as sensitive as many standard guinea pig assays. In addition, it is easier and much less expensive to perform. The vit A MESA has the sensitivity and predictive power needed to test compounds and mixtures for contact sensitizing potency.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparative sensitizing potencies of fragrances, preservatives, and hair dyes.

The local lymph node assay (LLNA) is used for assessing sensitizing potential in hazard identification and risk assessment for regulatory purposes. Sensitizing potency on the basis of the LLNA is categorized into extreme (EC3 value of ≤0.2%), strong (>0.2% to ≤2%), and moderate (>2%). To compare the sensitizing potencies of fragrance substances, preservatives, and hair dye substances, which are...

متن کامل

The noninvasive mouse ear swelling assay. I. Refinements for detecting weak contact sensitizers.

The noninvasive mouse ear swelling assay (MESA) is a model for delayed-type hypersensitivity that holds promise as a testing protocol for allergic contact dermatitis (ACD). The MESA employs only topical sensitization on the abdomen and does not use injections, adjuvants, anesthesia, occlusion, or disruption of the stratum corneum. Five days after induction, the ears are challenged topically and...

متن کامل

Skin sensitization in chemical risk assessment: report of a WHO/IPCS international workshop focusing on dose-response assessment.

An international workshop was held in 2006 to evaluate experimental techniques for hazard identification and hazard characterization of sensitizing agents in terms of their ability to produce data, including dose-response information, to inform risk assessment. Human testing to identify skin sensitizers is discouraged for ethical reasons. Animal-free alternatives, such as quantitative structure...

متن کامل

Lack of evidence for allergenic properties of coumarin in a fragrance allergy mouse model.

BACKGROUND There is controversy as to whether coumarin, an ingredient in cosmetics and fragrances, is a contact allergen involved in fragrance allergy. We recently showed that the purity of coumarin is a critical parameter for its allergenicity because coumarin preparations containing trace amounts of contaminants induced cell proliferation in the local lymph node (LN) assay whereas pure coumar...

متن کامل

Limonene hydroperoxide analogues differ in allergenic activity.

BACKGROUND The fragrance terpene R-limonene is a very weak sensitizer but forms allergenic oxidation products upon contact with air. Oxidized (ox.) limonene is a frequent cause of contact allergy in clinical testing. OBJECTIVES This study investigates the sensitizing potencies of ox. and non-ox. limonene and of structurally closely related limonene hydroperoxides. The clinical importance of t...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Fundamental and applied toxicology : official journal of the Society of Toxicology

دوره 17 4  شماره 

صفحات  -

تاریخ انتشار 1991