High-precision determination of the isotopic composition of dissolved iron in iron depleted seawater by double spike multicollector-ICPMS.
نویسندگان
چکیده
This work demonstrates the feasibility of the measurement of the isotopic composition of dissolved iron in seawater for an iron concentration range, 0.05-1 nmol L(-1), allowing measurements in most oceanic waters, including Fe depleted waters of high nutrient low chlorophyll areas. It presents a detailed description of our previously published protocol, with significant improvements on detection limit and blank contribution. Iron is preconcentrated using a nitriloacetic acid superflow resin and purified using an AG 1-x4 anion exchange resin. The isotopic ratios are measured with a multicollector-inductively coupled plasma mass spectrometer (MC-ICPMS) Neptune, coupled with a desolvator (Aridus II or Apex-Q), using a (57)Fe-(58)Fe double spike mass bias correction. A Monte Carlo test shows that optimum precision is obtained for a double spike composed of approximately 50% (57)Fe and 50% (58)Fe and a sample to double spike quantity ratio of approximately 1. Total procedural yield is 91 +/- 25% (2SD, n = 55) for sample sizes from 20 to 2 L. The procedural blank ranges from 1.4 to 1.1 ng, for sample sizes ranging from 20 to 2 L, respectively, which, converted into Fe concentrations, corresponds to blank contributions of 0.001 and 0.010 nmol L(-1), respectively. Measurement precision determined from replicate measurements of seawater samples and standard solutions is 0.08 per thousand (delta(56)Fe, 2SD). The precision is sufficient to clearly detect and quantify isotopic variations in the oceans, which so far have been observed to span 2.5 per thousand and thus opens new perspectives to elucidate the oceanic iron cycle.
منابع مشابه
High precision measurements of non-mass-dependent effects in nickel isotopes in meteoritic metal via multicollector ICPMS.
We measured the Ni isotopic composition of metal from a variety of meteorite groups to search for variations in the 60Ni abundance from the decay of the short-lived nuclide 60Fe (t(1/2) = 1.49 My) and for possible nucleosynthetic effects in the other stable isotopes of Ni. We developed a high-yield Ni separation procedure based on a combination of anion and cation exchange chromatography. Nicke...
متن کاملAnalytical developments for high-precision measurements of W isotopes in iron meteorites.
A procedure was developed to accurately measure the W isotopic compositions of iron meteorites with a precision of better than +/-0.1 epsilon on epsilon182W and epsilon184W (normalized to 186W/183W). Purification of W was achieved through a two-step, ion-exchange procedure. In most cases, the yield is better than 80%, and purified W solutions are clear of matrix elements and direct isobars of W...
متن کاملIron isotopes in the Amazon River system: Weathering and transport signatures
Trace metal clean plankton tows, river samples, aerosol leachates, and porewater samples from the Amazon River system were measured for their iron isotopic composition. The overall isotopic range observed was 1.5‰ with Fe isotopic variability observed between different types of tributaries. Dissolved Fe and suspended load Fe from two main channel sites were isotopically similar (≈ −0.1 to −0.3‰...
متن کاملDetermination of iron in seawater by high-resolution isotope dilution inductively coupled plasma mass spectrometry after Mg(OH)2 coprecipitation
A simple, accurate and highly sensitive method has been developed for determining the concentration of Fe in seawater. The technique applies the low-blank Mg(OH)2 coprecipitation method of Wu and Boyle [Anal. Chem. 69 (1997) 2464±2470] to preconcentrate Fe from seawater, and uses isotope dilution high-resolution ICPMS detection to ensure accuracy and enable high sensitivity. This method has bee...
متن کاملHigh Precision Ag Isotopic Measurements of Low Pd/Ag Meteorites
Introduction: The now extinct radionuclide Pd decays to Ag with a half life of 6.5Myr. Highly volatile element depleted (i.e. high Pd/Ag) Group IVA iron meteorites show good correlations between excess Ag and Pd/Ag. This strongly indicates the presence of live Pd at the start of the solar system [1]. Pd is both more refractory and more siderophile than Ag. Hence condensation/evaporation process...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Analytical chemistry
دوره 82 17 شماره
صفحات -
تاریخ انتشار 2010