Contribution of localized calcium deposits to dissection after angioplasty. An observational study using intravascular ultrasound.

نویسندگان

  • P J Fitzgerald
  • T A Ports
  • P G Yock
چکیده

BACKGROUND Atherosclerotic plaque fracture and dissection of the arterial wall are frequent concomitants of the balloon angioplasty process. The composition and morphology of plaque within the vessel may be critical in determining the extent of plaque fracture and dissection during balloon angioplasty. To examine this potential association in the clinical setting, we studied patients with intravascular ultrasound imaging after balloon angioplasty. METHODS AND RESULTS Forty-one patients were studied with intravascular ultrasound after angioplasty in both peripheral and coronary arteries. Ultrasound images representing the target lesion cross section were digitized, stored on computer, and analyzed off-line. The presence of intralesional calcium and the relative size of dissection for each lesion was computed. Thirty-one patients (76%) had ultrasound evidence of significant dissection or plaque fracture immediately after balloon dilation. In 23 of 31 (74%) of the lesions, the ultrasound scans showed significant localized calcium deposits within the plaque substance. In 87% of these cases, the dissections were adjacent to the calcific portion of the vessel wall. In addition, the relative size of dissections referenced to the neolumen area were significantly larger (p less than or equal to 0.002) in the calcified vessels (27.5 +/- 12.3%) compared with the size of the dissections in lesions without calcium (11.2 +/- 5.8%). CONCLUSIONS The presence of calcium within the vessel wall appeared to be significantly associated with both the location and size of the dissected tissue arm from the vessel wall. These data suggest that localized calcium deposits have a direct role in promoting dissection, presumably by increasing shear stresses within the plaque.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

An Observational Study Using Intravascular Ultrasound

Background. Atherosclerotic plaque fracture and dissection of the arterial wall are frequent concomitants of the balloon angioplasty process. The composition and morphology of plaque within the vessel may be critical in determining the extent of plaque fracture and dissection during balloon angioplasty. To examine this potential association in the clinical setting, we studied patients with intr...

متن کامل

Interobserver reproducibility of qualitative and quantitative analysis of intravascular ultrasound images before and after peripheral balloon angioplasty.

In this study, interobserver agreement on intravascular ultrasound data obtained before and after balloon angioplasty (PTA) of the superficial femoral artery was assessed. Two observers analyzed intravascular ultrasound cross-sections from 38 patients. Interobserver agreement was good for soft and hard lesions, dissection and vascular damage (kappa values 0.61, 0.67, 0.69 and 0.66, respectively...

متن کامل

Influence of plaque morphology on the mechanism of luminal enlargement after directional coronary atherectomy and balloon angioplasty.

OBJECTIVE To relate the mechanism of luminal gain after directional atherectomy and balloon angioplasty to the morphological characteristics of the coronary lesions, assessed by intravascular ultrasound imaging. DESIGN Intravascular ultrasound imaging was performed before and after the revascularisation procedure to assess the contribution of wall stretching and plaque reduction in luminal ga...

متن کامل

Target lesion calcification in coronary artery disease: an intravascular ultrasound study.

OBJECTIVES The purpose of this study was to evaluate the frequency, amount and distribution of target lesion calcification in patients undergoing transcatheter therapy for symptomatic coronary artery disease. BACKGROUND Coronary artery target lesion calcification may be an important determinant of response to transcatheter therapy: balloon angioplasty causes dissections in calcified lesions, ...

متن کامل

Morphological effects of coronary balloon angioplasty in vivo assessed by intravascular ultrasound imaging.

BACKGROUND Histological examination of the effects of balloon angioplasty have been described from in vitro experiments and a limited number of pathologic specimens. Intravascular ultrasound imaging permits real time cross-sectional observation of the effect of balloon dilation on the atherosclerotic plaque in vivo. METHODS AND RESULTS The morphological effects of coronary angioplasty were vi...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Circulation

دوره 86 1  شماره 

صفحات  -

تاریخ انتشار 1992