Proximal tendon-prosthesis junction for active tendon implants of the hand: a biomechanical comparison of 2 techniques.

نویسندگان

  • Matthew J Thompson
  • John R Owen
  • Charles L McDowell
  • Jennifer S Wayne
چکیده

PURPOSE To study the biomechanical characteristics (percent stretch, stiffness, and ultimate load) of 2 tendon-prosthesis techniques used to connect the proximal tendon stump to silicone active tendon implants used in reconstruction of flexor tendons. METHODS We evaluated percent stretch following cyclic loading and at failure, stiffness during load to failure, and ultimate load of 16 tendon-prosthesis junctions using cadaveric canine flexor digitorum profundus tendons to re-create 2 junction techniques: the tendon loop (TL) and the polyester weave (PW). RESULTS The TL junction showed greater percent stretch at a static load of 2 N, following 500 cycles of loading between 2 N and 50 N, and at peak load. The PW junction displayed greater stiffness from 50 to 150 N during load to failure. Both junctions failed at a mean ultimate load greater than 220 N. CONCLUSIONS The described proximal junction techniques for active tendon implants were strong enough to resist early active motion in the immediate postoperative period without significant elongation. The PW technique displayed greater stiffness and ultimate load compared with the TL. CLINICAL RELEVANCE Data on tendon-prosthesis characteristics of these 2 methods may aid the surgeon in choosing which junction technique to use, during surgical tensioning decisions, and in considering activity protocols after surgery. These data may also serve as a baseline for further investigations regarding active tendon implants.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Bone-Prosthesis Junction for Active Tendon Implants: A Biomechanical Comparison of 2 Fixation Techniques.

PURPOSE To study the biomechanical characteristics (percent stretch, stiffness, and ultimate load) of 2 distal fixation techniques for an active tendon implant used in the reconstruction of flexor tendons. METHODS We evaluated percent stretch after cyclical loading and at failure, stiffness during load-to-failure, and peak load of 28 bone-prosthesis junctions using cadaveric canine middle pha...

متن کامل

Evaluation of tendon healing using fibroblast like synoviocytes in rabbits: A biomechanical study

Tendon never restores the complete biological and mechanical properties after healing. Several techniques are available for tissue-engineered biological augmentation for tendon healing like stem cells. Recently, synovium has been investigated as a source of cells for tissue engineering. In the present study, we investigated potentials of fibroblast like synoviocytes (FLSs) in tendon healing. Si...

متن کامل

Autologous Platelet Rich Plasma Injection Improves Early Tendon Repair in Rabbits: A Histopathological and Biomechanical Study

Objective- The aim of this study was to investigate the PRP effects on the early time-period during tendon healing in rabbits DDF tendon. Design-Experimental study Animals- Twenty male New Zealand white rabbits Procedure-PRP samples were prepared using twice centrifugation method of modification of the Cuarsan...

متن کامل

Biomechanical Comparison Between Bashti Bone Plug Technique and Biodegradable Screw for Fixation of Grafts in Ligament surgery

  Background: Ligament reconstruction is a common procedure in orthopedic surgery. Although several popular techniques are currently in use, new methods are proposed for secure fixation of the tendon graft into the bone tunnel. Purposes: We sought to introduce our new technique of Bashti bone plug for fixation of soft tissue graft in anterior cruciate ligament (ACL) reconstruction and to compar...

متن کامل

Evaluation of Early Active Controlled Motion in Flexor Tendon Repair

Objectives: The objective was to determine the results of early active controlled motion in the patients rehabilitated by our new protocol. Methods: 91 fingers in 64 patients with flexor tendon repair in all zones were enrolled in a single group (quasi-experimental) clinical trial. 58 fingers in 43 patients were assessed at least three months postoperatively. Outcomes were defined using the ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The Journal of hand surgery

دوره 40 1  شماره 

صفحات  -

تاریخ انتشار 2015