Minimally invasive off-pump valve-in-a-ring implantation: the atrial transcatheter approach for re-operative mitral valve replacement after failed repair.

نویسندگان

  • Joerg Kempfert
  • Johannes Blumenstein
  • Michael W A Chu
  • Patrick Pritzwald-Stegmann
  • Tobias Kobilke
  • Volkmar Falk
  • Friedrich W Mohr
  • Thomas Walther
چکیده

OBJECTIVE Based upon recent developments in transcatheter technology, this study was designed to evaluate the feasibility and haemodynamic performance of transcatheter valve-in-a-ring (VinR) implantation for potentially failed mitral repair using a minimally invasive, transatrial, off-pump approach. METHODS Adult sheep (54.3+/-3.0 kg) underwent mitral valve repair with a 26 mm complete annuloplasty ring (Physio) using standard conventional techniques. To simulate the redo operation, a transcatheter 23 mm pericardial prosthesis (Edwards Sapien) mounted on a balloon-inflatable steel stent was deployed within the annuloplasty ring. VinR implantation was performed off-pump under rapid pacing in four and on-pump in three animals using an antegrade transatrial approach under fluoroscopic guidance. RESULTS Transcatheter VinR implantation was successful in all seven sheep. Mean transvalvular gradient was 4.9+/-0.3 mmHg. VinR function was excellent with no leak in one, good with mild leak in five (trans-stent: four, paravalvular: one) and sufficient with moderate central leak in one animal, respectively. Valve deployment required 10.0+/-0.7 min and all transcatheter prostheses were confirmed in good position on postmortem analysis, without any signs of valve dislocation or embolisation. In an in-vitro model, the minimum force required to dislodge the valve was 32.9+/-5.2N, which was well above the normal estimated forces generated by the left ventricle. One animal was kept alive to assess mid-term outcome and is still well 12 months after the VinR implantation. CONCLUSIONS Transatrial, transcatheter mitral VinR implantation is feasible using a minimally invasive off-pump approach. VinR implantation is a promising concept for re-operative surgery for selected patients after failed mitral valve repair.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

High-risk Coronary Artery Bypass Grafting and Mitral Valve Replacement in a HIV Positive Patient

Certain subsets of high-risk mitral valve patients are not suitable candidates for transcatheter therapies. The objective of this report is to present a young patient with combined mitral valve and coronary artery disease to illustrate these challenges.In this report, we present a 47-year-old man with longstanding HIV infection who was referred with severe mitral regurgitation (MR) and profound...

متن کامل

Minimally invasive and transcatheter techniques in high-risk cardiac surgery patients

Minimally invasive procedures have become pivotal in cardiac surgery, especially for the ever-increasing group of high-risk patients. These procedures are defined by the surgical access and/or the avoidance of cardiopulmonary bypass. Both of these aspects have been shown to be beneficial for patients with an increased perioperative risk. For high-risk patients with coronary artery disease, off-...

متن کامل

New Self-Expanding Transcatheter Valve for Off-Pump Transatrial Mitral Valve-In-Ring Implantation.

OBJECTIVES To validate a self-expanding transcatheter valve for off-pump transatrial mitral valve-in-ring (VIR) implantation via a left thoracotomy. METHODS Mitral valve annuloplasty was performed via sternotomy during cardiopulmonary bypass on 9 pigs. After successful weaning from extracorporal circulation, the custom-made, self-expanding transcatheter VIR device was deployed under fluorosco...

متن کامل

Transcatheter Mitral Valve Implantation

T he rationale for the development of a transcatheter mitral valve implantation (tMVI) procedure, either percutaneous or via minimally invasive surgery (MIS), arose from consideration of several key surgical concepts. First, mitral valve replacement is the most effective modality and the gold standard procedure for reliably reducing mitral regurgitation (MR). The efficacy and risks of mitral va...

متن کامل

Mitral valve disease, atrial fibrillation, and device therapy.

Transcatheter mitral interventions have been developed to address an unmet need, and as alternatives to surgery in patients at high risk or considered inoperable. Beyond MitraClip therapy, alternative repair technologies are being developed to expand the armamentarium of transcatheter intervention. Recently, the feasibility of transcatheter mitral valve implantation in native non-calcified valv...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • European journal of cardio-thoracic surgery : official journal of the European Association for Cardio-thoracic Surgery

دوره 35 6  شماره 

صفحات  -

تاریخ انتشار 2009