Six-year follow-up of endovenous laser ablation for great saphenous vein incompetence.

نویسندگان

  • Giorgio Spreafico
  • Andrea Piccioli
  • Enrico Bernardi
  • Enzo Giraldi
  • Patrizia Pavei
  • Riccardo Borgoni
  • Maurizio Ferrini
  • Ugo Baccaglini
چکیده

OBJECTIVE Treatment of chronic venous insufficiency of the great saphenous veins by endovenous laser ablation yields good short- and medium-term results, as assessed clinically and technically by echo-color-Doppler. At present, scarce data are available on the long-term results of endovenous laser ablation. We wanted to assess the long-term efficacy of endovenous laser ablation. METHODS We performed a prospective 6-year follow-up cohort study, with recruitment between 2003 and 2004, and the follow-up completed in 2010. The setting was an ambulatory care/day surgery. Of 209 consecutive patients who underwent endovenous laser ablation at our institution during the recruitment period, five (2.4%) did not complete the procedure due to technical reasons. Of 204 patients who successfully completed the intervention, 14 (6.8%) were lost for follow-up, and 190 completed the planned 6-year follow-up. The intervention was an endovenous laser ablation using a 980-nm laser diode. Clinical and echo-color-Doppler evaluations were regularly scheduled for all patients during the planned follow-up period. The incidence of clinical and echo-color-Doppler confirmed endovenous laser ablation failures over a 6-year follow-up period. Potential associations between failures and patients' characteristics, echo-color-Doppler findings, or surgical features were also investigated. RESULTS Symptomatic clinical endovenous laser ablation failures occurred in 22 (11.6%; 95% confidence interval [CI], 7.4-17.0%) patients; while 57 (30.0%; 95% CI, 23.6-37.1%) had echo-color-Doppler-confirmed failures. Only two patients (1.1%; 95% CI, 0.1%-3.8%) had both symptomatic clinical and echo-color-Doppler-confirmed failures. Three features of the great saphenous vein: an "atypical" junction, a junction diameter ≥8 mm, and a mean trunk diameter ≥8 mm, were independently associated with echo-color-Doppler-confirmed failures on multivariate logistic regression analysis. CONCLUSIONS Six years after endovenous laser ablation, most patients were improved on clinical grounds, and more than two-thirds had no saphenous insufficiency at echo-color-Doppler. Only a minority had both clinical and echo-color-Doppler-confirmed failures. Anatomical features of the junction and the saphenous diameter both at the junction and at the trunk independently predicted echo-color-Doppler-confirmed failures.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A novel endovenous laser ablation strategy of treatment of greater saphenous vein varicosities with difficult wire placement.

AIM To investigate the efficacy and early postoperative morbidity of a novel endovenous laser ablation (IEVLA) strategy of treatment of the great saphenous vein (GSV) with difficulty of wire placement. METHODS Sixty patients with serious GSV incompetence in 73 limbs were randomized into two treatment groups: Group 1 underwent traditional endovenous laser ablation (TEVLA) surgery and group 2 r...

متن کامل

Endovenous laser treatment of saphenous vein reflux: long-term results.

PURPOSE To report long-term follow-up results of endovenous laser treatment for great saphenous vein (GSV) reflux caused by saphenofemoral junction (SFJ) incompetence. MATERIALS AND METHODS Four hundred ninety-nine GSVs in 423 subjects with varicose veins were treated over a 3-year period with 810-nm diode laser energy delivered percutaneously into the GSV via a 600- micro m fiber. Tumescent ...

متن کامل

Mechanochemical endovenous Ablation versus RADiOfrequeNcy Ablation in the treatment of primary great saphenous vein incompetence (MARADONA): study protocol for a randomized controlled trial

BACKGROUND Radiofrequency ablation (RFA) is associated with an excellent outcome in the treatment of great saphenous vein (GSV) incompetence. The use of thermal energy as a treatment source requires the instillation of tumescence anesthesia. Mechanochemical endovenous ablation (MOCA) combines mechanical endothelial damage, using a rotating wire, with the infusion of a liquid sclerosant. Tumesce...

متن کامل

A multicenter, randomized, placebo-controlled trial of endovenous thermal ablation with or without polidocanol endovenous microfoam treatment in patients with great saphenous vein incompetence and visible varicosities

Objectives * Varithena 017 Investigator Group: Michael Vasquez, MD, Venous Institute of Buffalo, Amherst, NY; Antonios Gasparis, MD, Stony Brook University Medical Center, Stony Brook, NY; Kathleen Gibson, MD, Lake Washington Vascular, Bellevue, WA; James Theodore King, MD, Vein Clinics of America, Oakbrook Terrace, IL; Nick Morrison, MD, Morrison Vein Institute, Scottsdale, AZ; Girish Munavall...

متن کامل

Endovenous laser ablation of varicose veins with the 1470 nm diode laser using a radial fiber - 1-year follow-up.

BACKGROUND Endovenous laser ablation is one of the most accepted treatment options for insufficient great and small saphenous veins. The aim of this study was to investigate the long-term efficacy and safety of the radial fiber (ELVeS-radial kit™) for the 1470 nm diode laser in a 1-year follow-up. METHODS A total of 308 lower limbs with primary insufficiency of great and small saphenous veins...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of vascular surgery. Venous and lymphatic disorders

دوره 1 1  شماره 

صفحات  -

تاریخ انتشار 2013