Comparison of three commercially available peptide-based immunoglobulin G (IgG) and IgA assays to microimmunofluorescence assay for detection of Chlamydia trachomatis antibodies.

نویسندگان

  • Servaas A Morré
  • Christian Munk
  • Kenneth Persson
  • Susanne Krüger-Kjaer
  • Rogier van Dijk
  • Chris J L M Meijer
  • Adriaan J C van Den Brule
چکیده

Three commercially available, peptide-based enzyme-linked immunosorbent assay (ELISA) systems (Chlamydia trachomatis IgG and IgA EIA [CT-EIA; Labsystems OY, Helsinki, Finland], SeroCT IgG and IgA [SeroCT; Savyon Diagnostics Ltd., Ashdod, Israel], and Chlamydia trachomatis IgG and IgA pELISA [CT pELISA; Medac, Wedel, Germany]) were evaluated for the detection of serum immunoglobulin G (IgG) and IgA antibodies specific for Chlamydia trachomatis and compared to the "gold standard" assay, the microimmunofluorescence (MIF) assay. Serological responses were analyzed in 149 women aged 20 to 30 years. Cervical swabs obtained from these women were examined for C. trachomatis by PCR, and 43 were found to be positive. The overall seroprevalence rates detected by CT-EIA, SeroCT, CT pELISA, and the MIF assay were 42, 42, 35, and 39%, respectively, for IgG and 7, 7, 3, and 7%, respectively, for IgA. The IgG seroprevalence rates for the PCR-positive women were two to three times higher than those for the PCR-negative women, i.e., 72 versus 29%, 72 versus 29%, 47 versus 26%, and 74 versus 25% for CT-EIA, SeroCT, CT pELISA, and the MIF assay, respectively. After discrepancy analysis, the sensitivity, specificity, positive predictive value, and negative predictive value were calculated for the IgG assays; for CT-EIA they were 84.7, 98.6, 98.4, and 86.7%, respectively; for CT pELISA they were 71.4, 97.3, 96.2, and 78.3%, respectively; for SeroCT they were 84.7, 98.6, 98.4, and 86.3%, respectively; and for the MIF assay they were 79.2, 83.1, 98.3, and 83.1%, respectively. In conclusion, these peptide-based ELISA systems for the serological detection of C. trachomatis infection performed as well as the MIF assay. Since these tests are less time-consuming, less expensive, and easier to perform than the MIF assay, they might be useful in the serodiagnosis of chlamydial infection.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Molecular Evidence of Chlamydia trachomatis Infection and its Relation to Miscarriage

Objective Chlamydia trachomatis (CT) infection is the most common sexually transmitted disease in the world that can persist and also ascend in the genital tract. This intracellular and silent infection is related to some adverse pregnancy outcomes, such as miscarriage. The aims of this study were to explore the best CT screening tests using blood and vaginal samples and to investigate the corr...

متن کامل

Enzyme-linked immunosorbent assay for immunoglobulin G and M antibodies to Chlamydia trachomatis in human sera.

Microimmunofluorescence methods used for detection of immunoglobulin G and M antibodies to Chlamydia trachomatis are not available to many clinical laboratories. We evaluated a simple enzyme-linked immunosorbent assay in which serotype L2 elementary bodies are used as antigen. The enzyme-linked immunosorbent assay proved satisfactory for the detection of serum IgG. A total of 160 human sera wer...

متن کامل

Kinetic study of antibodies (IgG, IgA) to Chlamydia trachomatis: importance of IgA antibody in screening test for C. trachomatis infection by peptide-based enzyme immunosorbent assay.

To assess the importance of only IgA antibody positivity in the peptide-based ELISA (P-ELISA) examination of kinetic behaviors of antibodies (IgA, IgG) to Chlamydia trachomatis, 426 sera from 52 follow-up antigen-positive patients were assayed. In part, a microimmunofluorescence (MIF) test and an immunoblot (IB) assay were also used for confirmation. The results showed that the positivity rates...

متن کامل

Failure of serology in diagnosing chlamydial infections of the female genital tract.

Chlamydia trachomatis was recoved from 20% (36/180) of women attending a venereal disease clinic. All infected women had chlamydial antibodies in their serum and cervical secretions. However, the background rates of chlamydial antibody in chlamydia-negative women were very high. Measurement of antibodies in serum (complement fixation or immunoglobulin G [IgG] and IgM by microimmunofluorescence)...

متن کامل

Detection of Antibodies to Chlamydia trachomatis With Peptide-Based Species-Specific Enzyme Immunoassay

OBJECTIVE We have evaluated the sensitivity and specificity of a new synthetic peptide-based species-specific enzyme immunoassay (EIA) for detection of Chlamydia trachomatis IgG and IgA antibodies. METHODS Synthetic peptides derived from variable domain IV of major outer membrane protein (MOMP) were used as antigen in indirect EIA. IgG and IgA antibodies were measured in parallel with serum s...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Journal of clinical microbiology

دوره 40 2  شماره 

صفحات  -

تاریخ انتشار 2002