Mechanical tests on the tibial components of non-hinged knee prostheses.

نویسندگان

  • J H Bargren
  • W H Day
  • M A Freeman
  • S A Swanson
چکیده

Cadaveric knees replaced with the Geomedic, ICLH, Marmor and Total Condylar prostheses were tested in axial compression, in rotation and in hyperextension in order to observe the strength of fixation of the tibial components. In axial compression the strengths at failure varied widely, both with any one prosthesis and between prostheses. This is attributed largely to the strength of the cancellous bone of the tibia, which was measured in each case and also varied widely. Three natural knees failed at loads of 7300, 7600 and 8300 newtons respectively, whereas the strengths of replaced knees ranged from 3000 to 15750 newtons. At least one example of each design failed at less than 7300 newtons, suggesting little or no reserve of strength. The strength of fixation was greater when the tibial prosthesis was large enough to rest on the whole cross-section of the tibia. In rotation the three prostheses embodying rollers in troughs were stiffer than the Marmor which had a nearly flat tibial-bearing surface. The presence or absence of the cruciate ligaments had a negligible effect on torsional stiffness. In hyperextension, knees replaced with the ICLH, Marmor and Total Condylar prostheses failed by rupture of the posterior capsule at moments of about 60 newton-metres, compared with about 100 for natural knees. With the Marmor prosthesis the anterior cruciate ligament was avulsed at about 20 newton-metres compared with about 75 in natural knees, suggesting that in this respect the retention of the cruciate ligaments contributes little. None of the four knees tested after inserting a Geomedic prosthesis showed strengths as high as those replaced with the other three designs.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Morphology of proximal tibia in Iranian population and its corre-lation with available prostheses

  Background: Total knee arthroplasty is a complex procedure aiming to relieve pain and improve function. It is critical to select prosthesis that best cover the bone surfaces. Ethnicity may affect fitness of the components mainly designed for Caucasian populations. This study aimed to evaluate morphometric features of proximal tibia in Iranian population.   Methods : During 2013, 150 consecuti...

متن کامل

The Attenborough total knee replacement.

The stabilised gliding knee prosthesis is a compromise between hinged joints and condylar prostheses. It is a two-piece implant designed to allow normal gliding movements of flexion and extension and which, stabilised by a connecting rod between the femoral and tibial components, allows a designed laxity of rotation and lateral movements. A modification of the original femoral component is desc...

متن کامل

All-polyethylene tibial components in distal femur limb-salvage surgery: a finite element analysis based on promising clinical outcomes

BACKGROUND Whether all-polyethylene tibial (APT) components are beneficial to patients who received distal femur limb-salvage surgery lacks high-quality clinical follow-up and mechanical evidence. This study aimed to investigate the biomechanics of the distal femur reconstructed with APT tumor knee prostheses using finite element (FE) analysis based on our previous, promising clinical outcome. ...

متن کامل

Acute Primary Total Knee Arthroplasty for Proximal Tibial Fractures in Elderly

Background: Proximal tibial fractures in elderly patients with osteoporosis or knee osteoarthritis (OA) are challengingcases. In the current study, we present our experience with uncommon acute primary total knee arthroplasty (PTKA)in this patient population.Methods: PTKAs were performed following proximal tibial fractures in 30 consecutive patients over 60 years of agewith osteoporosis or knee...

متن کامل

Roentgen stereophotogrammetric analysis as a predictor of mechanical loosening of knee prostheses.

The tibial components in 143 patients with total knee replacements performed before 1988 were assessed for micromotion using roentgen stereophotogrammetric analysis (RSA) over a period of 13 years. The fixation of the prostheses remained clinically sound in all cases, although revision had been required for other reasons in seven. In a second group taken from all cases with RSA available on our...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The Journal of bone and joint surgery. British volume

دوره 60-B 2  شماره 

صفحات  -

تاریخ انتشار 1978