Iterative reconstruction with segmentation penalty for PET.

نویسندگان

  • Yueyang Teng
  • Yaonan Zhang
  • Yan Kang
چکیده

Segmentation technique is widely accepted to reduce noise propagation from transmission scanning for positron emission tomography. The conventional routine is to sequentially perform reconstruction and segmentation. A smoothness penalty is also usually used to reduce noise, which can be imposed to both the ML and WLS estimators. In this paper we replace the smoothness penalty by a segmentation penalty that biases the object toward piecewise-homogeneous reconstruction. Two updating algorithms are developed to solve the penalized ML and WLS estimates, which monotonically decrease the cost functions. Experimental results on simulated phantom and real clinical data were both given to demonstrate the effectiveness and efficiency of the algorithms which were proposed.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

MR-guided joint reconstruction of activity and attenuation in brain PET-MR

With the advent of time-of-flight (TOF) PET scanners, joint maximum-likelihood reconstruction of activity and attenuation (MLAA) maps has recently regained attention for the estimation of PET attenuation maps from emission data. However, the estimated attenuation and activity maps are scaled by unknown scaling factors. We recently demonstrated that in hybrid PET-MR, the scaling issue of this al...

متن کامل

Segmented Attenuation Correction for PET

We describe a hybrid measured/calculated method for attenuation correction in positron emission tomography (PET). This unified reconstruction/segmentation method is based on a penalized weighted least-squares (PWLS) objective function that is minimized using iterative coordinate-descent (ICD). Two penalty functions are compared; one for a discrete object parameterization, the other for a contin...

متن کامل

Joint image reconstruction and nonrigid motion estimation with a simple penalty that encourages local invertibility

Motion artifacts are a significant issue in medical image reconstruction. There are many methods for incorporating motion information into image reconstruction. However, there are fewer studies that focus on deformation regularization in motioncompensated image reconstruction. The usual choice for deformation regularization has been penalty functions based on the assumption that tissues are ela...

متن کامل

Comparison of threshold-based and watershed-based segmentation for the truncation compensation of PET/MR images

Recently introduced combined PET/MR scanners need to handle the specific problem that a limited MR field of view sometimes truncates arm or body contours, which prevents an accurate calculation of PET attenuation correction maps. Such maps of attenuation coefficients over body structures are required for a quantitatively correct PET image reconstruction. This paper addresses this problem by pre...

متن کامل

Nonnegative Definite Quadratic Penalty Design for Penalized-Likelihood Reconstruction

Likelihood-based estimators with conventional regularization methods generally produces images with nonuniform and anisotropic spatial resolution properties. Previous work on penalty design for penalizedlikelihood estimators has led to statistical reconstruction methods that yield approximately uniform “average” resolution. However some asymmetries in the local point-spread functions persist. S...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Bio-medical materials and engineering

دوره 26 Suppl 1  شماره 

صفحات  -

تاریخ انتشار 2015