Ion concentration polarization for pre-concentration of biological samples without pH change.
نویسندگان
چکیده
In this paper, a method was developed for pre-concentrating large-volume biological samples for subsequent analysis. We previously developed another pre-concentration device, but it unfortunately altered the pH of the sample when an electric field was applied to the sample reservoir. Changes in the pH are not suitable for subsequent antibody-antigen reactions because of the stability issues that arise based on the target molecule's isoelectric point (pI). Here, this problem was overcome using ion concentration polarization (ICP) with a cation selective membrane (Nafion). Phosphate buffered saline was used as a test solution for the sample. The sample was contained in a reservoir that was not affected by the electric field, and an ICP barrier was formed in front of the reservoir. This device could concentrate microliter-scale samples without changing the pH because the biomolecules were blocked from passing through the ICP barrier while the sample (phosphate buffered saline) was drained. A 40 μL sample was successfully pre-concentrated to 20 μL in a single channel device and 10 μL in a dual channel device, resulting in 2.1-fold and 3.3-fold increases, respectively, in influenza hemagglutinin concentrations. These changes in the concentration were confirmed by ELISA.
منابع مشابه
Application of Microfunnel Magnetic Stirring Assisted Liquid-Liquid Micro-extraction Method for Pre-concentration and Determination of Silver Ion in Water Samples
In this research, a highly sensitive, selective, rapid and simple micro-funnel magnetic stirringassisted liquid–liquid microextraction (MF-MSA-LLME) method combined with flame atomic absorption spectrometry (FAAS) was introduced for the preconcentration, extraction, and measurement of trace amounts of silver ion. In this method 1-(2–Pyridylazo)-2-naphthol (PAN) and 1-octanol were used as chelat...
متن کاملCharacterization and Assessment of Antimicrobial Activity and Potential of Heavy Metal ion Detection of Silver Nanoparticles synthesized from Actinidia deliciosa paste using double distilled water and 70% ethanol as solvent
Green synthesis of nanoparticles using plants as sources exhibiting superiority over the physical and chemical methods that are expensive and can involve the use of toxic, hazardous chemicals, which may pose biological and environmental risks. In present study silver nanoparticles were synthesized in single step by biological method using extracts of Actinidia deliciosa paste as reducing and st...
متن کاملDevelopment of dispersive liquid–liquid microextraction solidofied floating organic drop (DLLME SFOD) method for determination of cadmium in biological samples
Introduction: Todays, exposure to heavy metals is happened by being produced in various environmental, industrial processes. The production of metals finally results in air pollution as well as contamination in the food chain. There are harmful effects of heavy metals such as cadmium on different organs. Therefore, this study aimed to identify and quantify cadmium in biological samples using DL...
متن کاملBiological Removal of Dibenzothiophene from Soil and Changes to soil Sulfate by White-Rot Fungus Phanerochaete chrysosporium
This study investigated biodegradation of dibenzothiophene (DBT) in marsh soil spiked bywhite-rot fungus Phanerochaete chrysosporium. Soil samples were spiked with 100 ppm DBTand incubated at 30°C in a dark chamber for 30 days. Samples were evaluated for pH, Mnperoxidaseactivity, sulfate ion concentration and growth during the tests. Results showedmaximum levels of pH, Mn-peroxidase and sulfate...
متن کاملCopper concentration using micelle-mediated extraction in real samples
A simple and sensitive method is described for the pre-concentration by cloud point extraction followed by atomic absorption spectrometric determination of copper ion in real samples. At a solution pH of 5.5, 5, 5-diphenylimidazolidine-2, 4-dione (phenytoin) (DFID) and TritonX-114 were used as hydrophobic ligand and non-ionic surfactant. The adopted concentrations for DFID, Triton X-114 and HNO...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- The Analyst
دوره 141 24 شماره
صفحات -
تاریخ انتشار 2016