Simulation of Combined Shield Wire and MOV protection on Distribution Lines in Severe Lightning Areas

نویسندگان

  • Michael A. Omidiora
  • Matti Lehtonen
چکیده

This paper presents the protective effects of shield wire coupled with Metal Oxide Varistor (MOV) arresters in a distribution network located in a severe lightning area. The presented test case is the IEEE 34-node radial distribution test feeder injected with multiple lightning strokes and simulated with the Alternative Transients Program/ Electromagnetic Transients program (ATP/EMTP). The response of the distribution line to lightning strokes was modeled with three different cases: no protection, protection with surge arresters and protection with a combination of shield wire and arresters. Simulations were made to compare the resulting overvoltages on the line for all the analyzed cases.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Lightning Performance of High Voltage Transmission Lines Protected by Surge Arresters: a Simulation for the Hellenic Transmission Network

Lightning strikes to overhead transmission lines are a usual reason for unscheduled supply interruptions in the modern power systems. In an effort to maintain failure rates in a low level, providing high power quality and avoiding damages and disturbances, plenty of lightning performance estimation studies have been conducted and several design methodologies have been proposed. The protection o...

متن کامل

Performance of Surge Arrester to Multiple Lightning Strokes on Nearby Distribution Transformer

Overhead distribution lines are prone to lightning overvoltages due to their configurations and characteristics. Metal Oxide Varistor (MOVs) arresters for many years have proven to be more advantageous than others arresters in lightning surge protection; therefore it is worthwhile to continually assess the behavior and performance of these arresters to different kind of overvoltages caused by l...

متن کامل

Estimation of Charge during a Lightning Flash Using Electric Field Measurements

1 INTRODUCTION Electric power utilities have sustained significant damage from lightning. The occurrence of line faults is one result of lightning damage. To prevent it, power utilities adopt various measures of protection from lightning. Transmission line overhead ground wires greatly contribute to a decrease in the number of line faults by preventing direct hits to the power lines. Lightning ...

متن کامل

Sensitivity Assessment of Lightning Protection Device Aging Effect on Distribution Substation Insulation

 Insufficient electrical endurance of equipment and insulation failure against overvoltage is one of the most effective reasons for failure the power line. Lightening, switching or other disruptive parameters can cause line outage or distribution substation failure. There are different devices used to improve the safety, reliability, and power quality of the system. Surge arresters are one of t...

متن کامل

Lightning Protection of Ehv Substations in Iran

Extra high voltage (EHV) substations are extremely vulnerable to the hazard of lightning strokes therefore, the shielding of these substations with a highly reliable protective scheme (shield wires) is an essential undertaking. In this paper an attempt is made to clarify the design procedure for shielding EHV substations against lightning with special reference to Iran.

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2007