Comparison of a commercial blood cross-matching kit to the standard laboratory method for establishing blood transfusion compatibility in dogs.
نویسندگان
چکیده
OBJECTIVE To evaluate the accuracy of a commercial blood transfusion cross-match kit when compared to the standard laboratory method for establishing blood transfusion compatibility. DESIGN A prospective observational in intro study performed from July 2009 to July 2013. SETTING Private referral veterinary center. ANIMALS Ten healthy dogs, 11 anemic dogs, and 24 previously transfused dogs. INTERVENTIONS None. MEASUREMENT AND MAIN RESULTS Forty-five dogs were enrolled in a prospective study in order to compare the standard blood transfusion cross-match technique to a commercial blood transfusion cross-matching kit. These dogs were divided into 3 different groups that included 10 healthy dogs (control group), 11 anemic dogs in need of a blood transfusion, and 24 sick dogs that were previously transfused. Thirty-five dogs diagnosed with anemia secondary to multiple disease processes were cross-matched using both techniques. All dogs cross-matched via the kit had a compatible major and minor result, whereas 16 dogs out of 45 (35%) had an incompatible cross-match result when the standard laboratory technique was performed. The average time to perform the commercial kit was 15 minutes and this was 3 times shorter than the manual cross-match laboratory technique that averaged 45-50 minutes to complete. CONCLUSIONS While the gel-based cross-match kit is quicker and less technically demanding than standard laboratory cross-match procedures, microagglutination and low-grade hemolysis are difficult to identify by using the gel-based kits. This could result in transfusion reactions if the gel-based kits are used as the sole determinant of blood compatibility prior to transfusion. Based on our results, the standard manual cross-match technique remains the gold standard test to determine blood transfusion compatibility.
منابع مشابه
Cells O Antibody Screening Cells: A novel Approach to Antibody Screening
ABSTRACT Background and Objectives: Blood transfusion may induce some adverse effects on receivers. Some methods such as antibody screening and cross matching have been suggested to reduce the risk of transfusion complications. However, these methods require commercial antibody screening kits that may also need special equipment. The aim of this study was t...
متن کاملبررسی فراوانی تزریق خون و فرآوردههای آن در مرکزآموزشی درمانی شهدای عشایر خرمآباد در سه ماهه دوم سال 1389
Background : Blood is a resusciate source of life which there is no replacement for it. Limited time of preserving, screening tests of blood health, group determining, and cross-matching, that necessitate personal and laboratory costs, increase the importance of correct request and suitable consumption. This study was conducted to determine the frequency of blood transfusion and its components...
متن کاملComparison of Two ELISA Methods for the Laboratory Diagnosis of Acute Leptospirosis
Background: Leptospirosis is the most common zoonosis widespread in tropical and temperate countries with low social-economic status. We aimed to compare an ELISA kit with an in-house ELISA assay to test the serum samples of the patients who were suspicious of leptospirosis according to their clinical symptoms. Methods: A total of 282 serum samples of patients suspicious of leptospirosis admitt...
متن کاملA Survey on Transfusion Status in Orthopedic Surgery at a Trauma Center
Background: Increased costs and mortality associated with inappropriate blood transfusions have led to investigations about blood request and blood transfusion techniques. We investigated the transfusion status in patients who underwent orthopedic surgery in Poursina Hospital (Rasht, Iran) to optimizing blood usage and determine if a scheduled transfusion program for every orthopedic surgery ...
متن کاملComparison of Two Veterinary Blood Glucose Meters and One Human-Based Glucose Meter for Use in Dogs
Background: Recently, tendency to use veterinary specific Portable blood glucose meter (PBGMs) has increased. However, assessment of their analytical and clinical accuracy is a matter of concern. OBJECTIVES: To assess accuracy of two veterinary (AlphaTRAK2 and CERA-PET) and one human-based (Bionime) PBGMs for canine blood samples. METHODS: In this cross-sectional study, a total of 160 client-ow...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of veterinary emergency and critical care
دوره 26 2 شماره
صفحات -
تاریخ انتشار 2016