Regulation of middle cerebral artery blood velocity during recovery from dynamic exercise in humans.
نویسندگان
چکیده
We sought to examine the regulation of cerebral blood flow during 10 min of recovery from mild, moderate, and heavy cycling exercise by measuring middle cerebral artery blood velocity (MCA V). Transfer function analyses between changes in arterial blood pressure and MCA V were used to assess the frequency components of dynamic cerebral autoregulation (CA). After mild and moderate exercise, the decreases in mean arterial pressure (MAP) and mean MCA V (MCA Vm) were small. However, following heavy exercise, MAP was rapidly and markedly reduced, whereas MCA Vm decreased slowly (-23 +/- 4 mmHg and -4 +/- 1 cm/s after 1 min for MAP and MCA Vm, respectively; means +/- SE). Importantly, for each workload, the normalized low-frequency transfer function gain between MAP and MCA Vm remained unchanged from rest to exercise and during recovery, indicating a maintained dynamic CA. Similar results were found for the systolic blood pressure and systolic MCA V relationship. In contrast, the normalized low-frequency transfer function gain between diastolic blood pressure and diastolic MCA V (MCA Vd) increased from rest to exercise and remained elevated in the recovery period (P < 0.05). However, MCA Vd was quite stable on the cessation of exercise. These findings suggest that MCA V is well maintained following mild to heavy dynamic exercise. However, the increased transfer function gain between diastolic blood pressure and MCA Vd suggests that dynamic CA becomes less effective in response to rapid decreases in blood pressure during the initial 10 min of recovery from dynamic exercise.
منابع مشابه
Dynamic cerebral autoregulation during and after handgrip exercise in humans.
The purpose of the present study was to examine the effect of static exercise on dynamic cerebral autoregulation (CA). In nine healthy subjects at rest before, during, and after static handgrip exercise at 30% maximum voluntary contraction, the response to an acute drop in mean arterial blood pressure and middle cerebral artery mean blood velocity was examined. Acute hypotension was induced non...
متن کاملRegulation of middle cerebral artery blood velocity during dynamic exercise in humans: influence of aging.
Although cerebral autoregulation (CA) appears well maintained during mild to moderate intensity dynamic exercise in young subjects, it is presently unclear how aging influences the regulation of cerebral blood flow during physical activity. Therefore, to address this question, middle cerebral artery blood velocity (MCAV), mean arterial pressure (MAP), and the partial pressure of arterial carbon...
متن کاملMiddle cerebral artery flow velocity and pulse pressure during dynamic exercise in humans.
Exercise challenges cerebral autoregulation (CA) by a large increase in pulse pressure (PP) that may make systolic pressure exceed what is normally considered the upper range of CA. This study examined the relationship between systolic blood pressure (SBP), diastolic blood pressure (DBP), and mean arterial pressure (MAP) and systolic (V(s)), diastolic (V(d)). and mean (V(m)) middle cerebral art...
متن کاملComparison of flow and velocity during dynamic autoregulation testing in humans.
BACKGROUND AND PURPOSE We compared relative changes in middle cerebral artery velocity and internal carotid artery flow during autoregulation testing to test the validity of using transcranial Doppler recordings of middle cerebral artery velocity to evaluate cerebral autoregulation in humans. METHODS Seven human volunteers had dynamic autoregulation tested during surgical procedures that incl...
متن کاملDynamic cerebral autoregulation during exhaustive exercise in humans.
We investigated whether dynamic cerebral autoregulation is affected by exhaustive exercise using transfer-function gain and phase shift between oscillations in mean arterial pressure (MAP) and middle cerebral artery (MCA) mean blood flow velocity (V(mean)). Seven subjects were instrumented with a brachial artery catheter for measurement of MAP and determination of arterial Pco(2) (Pa(CO(2))) wh...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of applied physiology
دوره 102 2 شماره
صفحات -
تاریخ انتشار 2007