Dose-response relationships in an olfactory flux detector model revisited.

نویسندگان

  • Karl-Ernst Kaissling
  • Jean-Pierre Rospars
چکیده

A simple model of an odorant flux detector including odorant uptake, activation of odorant receptor molecules and enzymatic odorant deactivation can produce different types of static dose-response relationships. Depending on the binding characteristics of the odorant to the receptor molecule and to the deactivating enzyme, the receptor occupation by the odorant as related to the odorant uptake is quasi-hyperbolic, linear or, close to saturation, steeper than linear. In Rospars et al. (2003, Chem. Senses, 28: 509-522) a note contributed by both of us stated erroneously that an equation describing these relationships given previously (Kaissling, 1998, Chem. Senses, 23; 99-111; Kaissling, 2001, Chem. Senses, 26: 125-150) was incorrect. We show here that the difference in equations was due to a simplifying assumption in Rospars et al. (2003) about the deactivating enzyme, we summarize briefly the properties of the correct equation of Kaissling (1998, 2001) and we discuss the relation with the model studied in Rospars et al. (2003).

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Determination of the flux of a neutron radioisotope source through gold activation method

Introduction: In recent years, the use of neutrons has increased in various fields such as medicine and industry. One of the important applications of neutrons is in medical research. Neutrons have greater linear energy transfer than gamma rays and are considered more dangerous radiation. Hence, the detection and determination of neutron dose is a very important and vital issu...

متن کامل

Photon dosimetry based on selective data sampling for the NaI(TL) detector

Radiation detection is essential for determining of radiation dose. Depend on the detector and dosimetry method, detection process is performed in different levels. Pulse counting is the first level of detection. Typically, the output of a radiation detector for determining value of the radiation dose cannot be used directly. Through changing the response function or the readout detector, is tr...

متن کامل

Assessment of Olfactory Threshold in Patients Undergoing Radiotherapy for Head and Neck Malignancies

Introduction: Radiotherapy is a common treatment modality for patients with head and neck malignancies. As the nose lies within the field of radiotherapy of the head and neck, the olfactory fibers and olfactory receptors may be affected by radiation. The aim of this study was to evaluate changes in olfactory threshold in patients with head and neck malignancies who have received radiation to th...

متن کامل

Study on effect of detector type in estimating buildup factor of gamma-rays by monte carlo simulation based on variance reduction

This paper presents the study on the effect of detector type in estimating gamma rays buildup factor. In this regard, the flux buildup factors of gamma rays emitted by an isotropic point 60Co source in mean energy 1.253 MeV was evaluated after passing through the Pb, W, Zn, and Ti sample in thickness of 1-5 cm by MCNPX. Four common detector types in simulation of measurement was defined to esti...

متن کامل

Measurement of stereotactic beam data of 9 MV X-rays using diode detector

Background: Radiosurgery is a focal brain irradiation technique that delivers, usually in a single session, high dose of ionizing radiation. The presence of lateral electronic disequilibrium and steep dose gradients in small fields demands special attention to the selection of a suitable detector with respect to its size, composition and response. Materials and Methods : Small circular fields w...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Chemical senses

دوره 29 6  شماره 

صفحات  -

تاریخ انتشار 2004