Comparison of the MGIT 960, BACTEC 460 TB and solid media for isolation of Mycobacterium bovis in United States veterinary specimens

نویسندگان

  • Suelee Robbe-Austerman
  • Doris M Bravo
  • Beth Harris
چکیده

BACKGROUND Bacteriologic culture remains one of the most important methods to diagnose bovine tuberculosis despite the lengthy incubation time, significant decontamination and media expense, and high biocontainment requirements. Media selection is an important determination of culture sensitivity, and the planned discontinuation of the BACTEC 460 TB culture system has challenged veterinary diagnostic laboratories to evaluate alternatives. At the National Veterinary Services Laboratories the BACTEC MGIT 960 and 4 solid media formulations were compared with the BACTEC 460 TB system on 6,795 veterinary diagnostic specimens submitted for Mycobacterium bovis culture. RESULTS M. bovis was isolated from 2.6% of the samples and atypical mycobacteria from 4.4% of the samples. The BACTEC 12B media isolated significantly more M. bovis (93.1% of positive samples) than MGIT 960 media (81.9%). However, contamination rates were much higher for the MGIT media, 17-24%, compared to 7% for BACTEC, suggesting that contamination was a major cause of MGIT reduced sensitivity. Time to signal positive was 2.37 weeks (95% CI 2.24-2.5) for the MGIT, and 3.2 weeks (95% CI 3.07-3.3) for the BACTEC, both earlier than any solid media. Mycobactosel LJ failed to isolate M. bovis from primary culture. An in-house 7H11 media supplemented with calf sera, hemolyzed blood, malachite green and pyruvate recovered more M. bovis (80.6%) with the least amount of contamination of any other solid media evaluated. CONCLUSION Decontamination methods may have to be optimized and or MGIT media may have to be altered to reduce contamination in veterinary samples. Despite these issues, the MGIT 960 system is still favored over the use of solid media due to decreased time to recovery and the potential for higher sensitivity.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of the recovery of Mycobacterium bovis isolates using the BACTEC MGIT 960 system, BACTEC 460 system, and Middlebrook 7H10 and 7H11 solid media.

The BACTEC Microbacteria Growth Indicator Tube (MGIT) 960 system was evaluated to determine how it compares with the BACTEC 460 radiometric system and solid media for recovery of Mycobacterium bovis from tissue samples. A total of 506 bovine lymph node samples were collected from abattoirs in the United States and Mexico between November 2003 and September 2004. Processed samples were inoculate...

متن کامل

Multicenter evaluation of the BACTEC MGIT 960 system for recovery of mycobacteria.

We evaluated the BACTEC MGIT 960 system, which is a fully automated, noninvasive system for the growth and detection of mycobacteria with a capacity to incubate and continuously monitor 960 7-ml culture tubes. We studied 3,330 specimens, 2,210 respiratory and 1,120 nonrespiratory specimens, collected from 2,346 patients treated at six sites. Processed specimens were inoculated into the BACTEC M...

متن کامل

Comparison of recoveries of mycobacterium tuberculosis using the automated BACTEC MGIT 960 system, the BACTEC 460 TB system, and Löwenstein-Jensen medium.

Using two different liquid media and one conventional solid medium, a total of 57 mycobacterial isolates (Mycobacterium tuberculosis, n = 55; nontuberculous mycobacteria, n = 2) were recovered from 377 clinical specimens. The rates of recovery of M. tuberculosis were 96. 4% with the BACTEC MGIT 960 liquid medium, 92.7% with BACTEC 12B liquid medium, and 81.8% with the Löwenstein-Jensen (LJ) med...

متن کامل

Comparison of BACTEC MGIT 960 system and BACTEC 460 TB system for growth and detection of Mycobacteria from clinical specimens.

This study was carried out to compare the performance of BACTEC MGIT 960 with the BACTEC 460 TB for growth and detection of Mycobacteria from human clinical specimens. The BACTEC MGIT 960 instrument is a fully automated system that utilizes MGIT tubes containing an oxygen sensor embedded in silicon at the bottom and filled with 7 mL of modified Middlebrook 7H9 broth. Identical samples were inoc...

متن کامل

Meta-analysis of BACTEC MGIT 960 and BACTEC 460 TB, with or without solid media, for detection of mycobacteria.

In a meta-analysis of 10 studies, the BACTEC 960/MGIT and BACTEC 460 systems showed a sensitivity and specificity in detecting mycobacteria (1,381 strains from 14,745 clinical specimens) of 81.5 and 99.6% and 85.8 and 99.9%, respectively. Combined with solid media, the sensitivity of the two systems increased to 87.7 and 89.7%, respectively.

متن کامل