Modified handling of internal catecholamine standards in radioenzymic assays.
نویسندگان
چکیده
A departure from a radioenzymic procedure widely used for plasma catecholamine assay is reported, in which we use "mean net standards" instead of individual internal standards. Interlaboratory/intermethod analyses validated use of the modified principle and demonstrated its preferential use over the conventional principle. Also demonstrated is use of the modified procedure for calculating catecholamine concentrations of several plasma samples collected from an exercising man and an acceleration-stressed swine. Benefits already derived from use of the procedure include: (a) quantification of certain plasma samples that could not be satisfactorily quantified by conventional options, (b) an apparent gain in analytical precision in virtually all other analyses, and (c) costs of analysis reduced by about 25%.
منابع مشابه
Radioenzymic measurement of norepinephrine, epinephrine, and dopamine: stability, enzymic activity, and sensitivity.
We investigated factors affecting sensitivity and reproducibility of radioenzymic (catechol-O-methyltransferase) measurement of plasma catecholamines. There was no apparent deterioration of catecholamine during storage at -20 degrees C for 240 days. Accuracy and sensitivity of the assay depended mostly on the method of transferase preparation; its preparation by adjusting the pH to 6.8 before f...
متن کاملKinetics of enzymatic O-methylation: its value in assays for catecholamines in plasma.
The kinetics of enzymatic O-methylation of catecholamines were studied under conditions like those used in the radioenzymatic assay of plasma catecholamines. Inappropriate Michaelis-Menten kinetics and linear approximations of exponential equations were not used. Mathematical analysis indicated the importance of the ratio of methyl donor (S-adenosylmethionine) to substrate (catecholamine) conce...
متن کاملCatecholamine sulfates as internal standards in HPLC determinations of sulfoconjugated catecholamines in plasma and urine.
A method is described to measure catecholamine sulfates from human plasma and urine by isocratic reversed-phase high-performance liquid chromatography with electrochemical detection. For this measurement we use catecholamine 3-sulfate isomers as internal standards and determine the sulfoconjugates only after eliminating the catecholamines. Catecholamines that have previously been used as intern...
متن کاملDilution of plasma with Tris buffer increases measured catecholamines in plasma.
We investigated the effects of dilution of plasma samples on the measured concentrations of catecholamines. Diluting samples of human plasma 10-, 50-, and 100-fold with Tris buffer (100 mol/L, pH 8.6) improved analytical recovery of internal standards, suggesting that it decreases the commonly observed inhibition of methylation in radioenzymatic assays of catecholamines in plasma. However, the ...
متن کاملPhase-Destabilization Mechanism of Polymer-Modified Bitumens in Quiescent Annealing
Bitumen as a binder in coating and insulating materials is modified with polymers to improve its performance in service conditions. Almost all polymers are incompatible with bitumen, and at high temperatures due to relatively very low viscosity of the bitumen phase, are separated from it. These lead to a considerable limitation in the use and handling of polymer-modified bitumens. An understand...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Clinical chemistry
دوره 29 1 شماره
صفحات -