An assessment of radial haemolysis in the detection of rubella antibody.

نویسندگان

  • B Gee
  • B E Jordan
  • P R Mortimer
چکیده

The results obtained by radial haemolysis in the detection of antibodies to rubella virus compared well with those obtained by haemagglutination inhibition. Radial haemolysis is unaffected by non-specific inhibitors. The sera do not therefore require pretreatment and the results are less equivocal. Radial haemolysis appears to be as sensitive as immunofluorescence and floatation centrifugation. It is possible to examine large numbers of sera with a considerable saving of time compared with the traditional haemagglutination technique. Rheumatoid factor may cause interference in radial haemolysis. Immune sera may be recorded as non-immune. This interference can be removed by 2-mercaptoethanol or reduced by heating sera at 60 degrees C for 20 minutes.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The use of single-radial-haemolysis for rubella antibody studies.

The use of a single-radial-haemolysis technique for the detection of antibody to rubella virus is described. The single-radial-haemolysis test was compared with the standard HI methods for the detection of antibody to rubella virus. A close correlation between the two methods was observed in a survey of over two thousand serum samples and the study indicated that single-radial-haemolysis was hi...

متن کامل

Comparison of radial haemolysis with haemagglutination inhibition in estimating rubella antibody.

Radial haemolysis (RH) for assaying rubella antibody was studied in parallel tests with haemagglutination-inhibition (HAI) on 1102 sera from adult women. Simple to perform and economical in reagents, the RH test is as sensitive as the HAI test and is a useful method of screening antenatal and other sera for rubella immunity. It detects IgG but not IgM antibody.

متن کامل

Evaluation of the single radial haemolysis (SRH) technique for rubella antibody measurement.

Sera from 1258 individuals have been tested by four laboratories for rubella antibody by both the haemagglutination-inhibition and single radial haemolysis techniques. There was good agreement between the results obtained by the two methods. Although sheep red blood cells were used in the single radial haemolysis plates, no problems were encountered with sera from patients with infectious monon...

متن کامل

Determination of frequency the non-immune to rubella in 14-18 years old girls in rafsanjan city 1379

 Background and objective: Congenital Rubella Syndrom (CSR) could be  prevented if young women knew their immune status befor pregnancy,contributing in this way to decrease the birth morbidity rate due to CRS amonge the children.  Method: In order to determination the level of antibody or immunity to rubella in  rafsanjan city,270 sera of 14-18 years old girls were evaluated reterospectivly.EL...

متن کامل

Rubella antibody determination from heparinised finger-tip blood by single radial haemolysis and enzyme immunoassay.

Rubella antibodies were determined by single radial haemolysis (SRH) and a micromodification of enzyme immunoassay (EIA) of samples of heparinised finger-tip blood or plasma collected into transportable vials, and the results were compared with antibody titres obtained from conventional samples of venous serum. The antibody titres of finger-tip specimens gave a high correlation with those of ve...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of clinical pathology

دوره 31 1  شماره 

صفحات  -

تاریخ انتشار 1978