Enhanced phase-sensitive SSFP reconstruction for fat-water separation in phased-array acquisitions.

نویسندگان

  • Ozgur Yilmaz
  • Emine Ulku Saritas
  • Tolga Çukur
چکیده

PURPOSE To propose and assess a method to improve the reliability of phase-sensitive fat-water separation for phased-array balanced steady-state free precession (bSSFP) acquisitions. Phase-sensitive steady-state free precession (PS-SSFP) is an efficient fat-water separation technique that detects the phase difference between neighboring bands in the bSSFP magnetization profile. However, large spatial variations in the sensitivity profiles of phased-array coils can lead to noisy phase estimates away from the coil centers, compromising tissue classification. MATERIALS AND METHODS We first perform region-growing phase correction in individual coil images via unsupervised selection of a fat-voxel seed near the peak of each coil's sensitivity profile. We then use an optimal linear combination of phase-corrected images to segregate fat and water signals. The proposed method was demonstrated on noncontrast-enhanced SSFP angiograms of the thigh, lower leg, and foot acquired at 1.5T using an 8-channel coil. Individual coil PS-SSFP with a common seed selection for all coils, individual coil PS-SSFP with coil-wise seed selection, PS-SSFP after coil combination, and IDEAL reconstructions were also performed. Water images reconstructed via PS-SSFP methods were compared in terms of the level of fat suppression and the similarity to reference IDEAL images (signed-rank test). RESULTS While tissue misclassification was broadly evident across regular PS-SSFP images, the proposed method achieved significantly higher levels of fat suppression (P < 0.005) and increased similarity to reference IDEAL images (P < 0.005). CONCLUSION The proposed method enhances fat-water separation in phased-array acquisitions by producing improved phase estimates across the imaging volume. J. Magn. Reson. Imaging 2016;44:148-157.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Robust Multicoil Reconstruction for Phase-Sensitive Fat-Water Separation

Introduction: Phase-sensitive (PS) SSFP [1,2] is an efficient fat/water separation method, successfully used in several applications including angiography [1], musculoskeletal [3] and abdominal [4] imaging. It generates and detects a 180 phase-difference between fat and water. In previous work, water images reconstructed from individual coils with PSSSFP were combined [4,5]. However, abrupt spa...

متن کامل

Fat Suppression for Non-contrast-enhanced Peripheral Angiography: Phase-sensitive versus IDEAL SSFP

Introduction: MR angiography is a valuable tool in the diagnosis of vascular diseases. Non-contrast-enhanced flow-independent peripheral angiograms can be produced with magnetization-prepared balanced SSFP if the bright fat signal is suppressed [1]. However, poor fat suppression and banding artifacts can be observed with field inhomogeneity (e.g., over large FOVs). In this work, we compare two ...

متن کامل

Water-Fat Separation Using a Locally Low-Rank Enforcing Reconstruction

INTRODUCTION: Multi-contrast water-fat separation based on the Dixon method is steadily gaining importance in clinical routine. An accelerated examination using dedicated acquisition schemes in combination with an iterative reconstruction is therefore highly desirable. A direct reconstruction of water and fat images incorporating field inhomogeneities, relaxation effects as well as gradient del...

متن کامل

Fat-suppressed steady-state free precession imaging using phase detection.

Fully refocused steady-state free precession (SSFP) is a rapid, efficient imaging sequence that can provide diagnostically useful image contrast. In SSFP, the signal is refocused midway between excitation pulses, much like in a spin-echo experiment. However, in SSFP, the phase of the refocused spins alternates for each resonant frequency interval equal to the reciprocal of the sequence repetiti...

متن کامل

Phased array antenna using MEMS phase shifter

This article presents a phased array antenna employing MEMS phase shifter. The proposed phased array antenna consists of eight square patch antennas operating at 10.4 GHz with a bandwidth of 400 MHz. Feed line for each patch passes through a MEMS phase shifter realized by a series of bridges above the transmission line. The distance between the bridge and the transmission line underneath it is ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of magnetic resonance imaging : JMRI

دوره 44 1  شماره 

صفحات  -

تاریخ انتشار 2016