Macular Bruch´s Membrane Length and Axial Length. The Beijing Eye Study

نویسندگان

  • Jost B. Jonas
  • Ya Xing Wang
  • Qi Zhang
  • Yi Liu
  • Liang Xu
  • Wen Bin Wei
  • Chen-Wei Pan
چکیده

PURPOSE To assess whether macular Bruch´s membrane gets lengthened in axial myopia. METHODS Using the enhanced depth imaging mode of spectral-domain optical coherence tomography and examining a subgroup of participants of the population-based cross-sectional Beijing Eye Study, we measured the length of Bruch´s membrane ("MacBMLength") from the fovea to the temporal edge of parapapillary gamma zone, and the distance between the fovea and the temporal optic disc border. Parapapillary gamma zone was defined as the parapapillary region without Bruch's membrane. We additionally measured ocular biometric parameters and assessed non-ophthalmologic variables. RESULTS Measurements of MacBMLength were performed on 322 individuals. MacBMLength (mean: 3.99 ± 0.33 mm; range: 3.17-4.93 mm) was not significantly associated with any systemic parameter or ocular biometric parameter. Gamma zone width (mean: 0.18 ± 0.30 mm; range: 0.00-2.61 mm) was associated (multivariate analysis; correlation coefficient r:0.80) with longer axial length (P<0.001; standardized correlation coefficient beta: 0.60; non-standardized correlation coefficient B:0.11; 95%CI: 0.09,0.14) and with longer fovea-optic disc border distance (P<0.001; beta:0.28; B:0.19; 95%CI:0.14,0.25), but not with MacBMLength (P = 0.42). Fovea-temporal disc border distance (mean: 4.16 ± 0.44 mm; range: 3.17-5.86 mm) was associated (overall correlation coefficient: 0.68) with longer axial length (P<0.001; beta: 0.36; B: 0.10; 95%CI: 0.06, 0.13), after adjusting for flatter anterior chamber depth (P = 0.003; beta:-0.14; B:-0.14; 95%CI: -0.23,-0.05) and wider parapapillary gamma zone (P<0.001; beta:0.42; B:0.62; 95%CI:0.44,0.81). CONCLUSIONS In contrast to parapapillary gamma zone width and fovea-disc border distance, MacBMLength was not significantly associated with axial length. Axial elongation associated increase in fovea-disc distance may predominantly occur through development or elongation of parapapillary gamma zone, while macular Bruch´s membrane may mostly be independent of axial elongation.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Horizontal and vertical optic disc rotation. The Beijing Eye Study

PURPOSE To measure the optic disc rotation around the vertical and horizontal disc axis and to evaluate associations with general and ocular parameters. DESIGN Population-based study. METHODS In the Beijing Eye Study, 3468 participants (mean age:64.6±9.8 years; range:50-93 years) underwent an ophthalmological examination which included spectral-domain optical coherence tomography (OCT) with...

متن کامل

Optic Disc - Fovea Distance, Axial Length and Parapapillary Zones. The Beijing Eye Study 2011

PURPOSE To measure the distance between the optic disc center and the fovea (DFD) and to assess its associations. METHODS The population-based cross-sectional Beijing Eye Study 2011 included 3468 individuals aged 50+ years. The DFD was measured on fundus photographs. RESULTS Readable fundus photographs were available for 2836 (81.8%) individuals. Mean DFD was 4.76 ± 0.34 mm (median: 4.74 mm...

متن کامل

Axial and Posterior Wall Thickness Elastic Modulus of Eyes in Age-related Macular Degeneration (ARMD) Patients Compared to Healthy Individuals Using Ultrasound Images

Background & Aims: Age-related macular degeneration (ARMD) is one of the common retina disorders that can lead to loss of vision by increase in age. In this study, the efficacy of a non-invasive ultrasound technique for the evaluation of alastic properties of eye in the diagnosis of ARMD has been evaluated. Methods: For estimation of the elastic modulus of eye, spatial loading system designed a...

متن کامل

Parapapillary Gamma Zone and Axial Elongation-Associated Optic Disc Rotation: The Beijing Eye Study.

PURPOSE The parapapillary gamma zone has been defined as the parapapillary region without Bruch's membrane. We examined which morphologic parameters are associated with the presence and size of the parapapillary gamma zone. METHODS Using fundus photographs and spectral-domain optical coherence tomographic images of the optic nerve head in the population-based Beijing Eye Study, we determined ...

متن کامل

Bruch´s membrane thickness in relationship to axial length

PURPOSE To assess a potential role of Bruch´s membrane (BM) in the biomechanics of the eye, we measured its thickness and the density of retinal pigment epithelium (RPE) cells in various ocular regions in eyes of varying axial length. METHODS Human globes, enucleated because of an ocular tumor or end-stage glaucoma were prepared for histological examination. Using light microscopy, the histol...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 10  شماره 

صفحات  -

تاریخ انتشار 2015