Transplacental transfer of cobalt and chromium in patients with metal-on-metal hip arthroplasty: a controlled study.

نویسندگان

  • H Ziaee
  • J Daniel
  • A K Datta
  • S Blunt
  • D J W McMinn
چکیده

Metal-on-metal bearings are being increasingly used in young patients. The potential adverse effects of systemic metal ion elevation are the subject of ongoing investigation. The purpose of this study was to investigate whether cobalt and chromium ions cross the placenta of pregnant women with a metal-on-metal hip resurfacing and reach the developing fetus. Whole blood levels were estimated using high-resolution inductively-coupled plasma mass spectrometry. Our findings showed that cobalt and chromium are able to cross the placenta in the study patients with metal-on-metal hip resurfacings and in control subjects without any metal implants. In the study group the mean concentrations of cobalt and chromium in the maternal blood were 1.39 microg/l (0.55 to 2.55) and 1.28 microg/l (0.52 to 2.39), respectively. The mean umbilical cord blood concentrations of cobalt and chromium were comparatively lower, at 0.839 microg/l (0.42 to 1.75) and 0.378 microg/l (0.14 to 1.03), respectively, and this difference was significant with respect to chromium (p < 0.05). In the control group, the mean concentrations of cobalt and chromium in the maternal blood were 0.341 microg/l (0.18 to 0.54) and 0.199 microg/l (0.12 to 0.33), and in the umbilical cord blood they were 0.336 microg/l (0.17 to 0.5) and 0.194 microg/l (0.11 to 0.56), respectively. The differences between the maternal and umbilical cord blood levels in the controls were marginal, and not statistically significant (p > 0.05). The mean cord blood level of cobalt in the study patients was significantly greater than that in the control group (p < 0.01). Although the mean umbilical cord blood chromium level was nearly twice as high in the study patients (0.378 microg/l) as in the controls (0.1934 microg/l), this difference was not statistically significant. (p > 0.05) The transplacental transfer rate was in excess of 95% in the controls for both metals, but only 29% for chromium and 60% for cobalt in study patients, suggesting that the placenta exerts a modulatory effect on the rate of metal ion transfer.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Large head metal-on-metal cementless total hip arthroplasty versus 28mm metal-on-polyethylene cementless total hip arthroplasty: design of a randomized controlled trial

BACKGROUND Osteoarthritis of the hip is successfully treated by total hip arthroplasty with metal-on-polyethylene articulation. Polyethylene wear debris can however lead to osteolysis, aseptic loosening and failure of the implant. Large head metal-on-metal total hip arthroplasty may overcome polyethylene wear induced prosthetic failure, but can increase systemic cobalt and chromium ion concentr...

متن کامل

Elevation of circulating HLA DR+ CD8+ T-cells and correlation with chromium and cobalt concentrations 6 years after metal-on-metal hip arthroplasty

BACKGROUND AND PURPOSE Following metal-on-metal hip arthroplasty (THA), immunological reactions including changes in lymphocyte populations, aseptic loosening, and lymphocytic pseudotumors occur. We hypothesized that changes in lymphocyte subpopulations would be associated with elevated metal ion concentrations. METHODS A randomized trial involving 85 patients matched for age and sex and rand...

متن کامل

Fatal Cobalt Cardiomyopathy Following Revision Total Hip Arthroplasty – A Brief Report with Review of Literature

Ceramic bearing surfaces are being increasingly used in young patients undergoing total hip arthroplasty. However,failures have been reported including fractures even with the newer third generation ceramics. The recommendedtreatment for fracture of ceramic bearing surfaces is complete synovectomy and revision total hip arthroplasty.However, disappointing results have also bee...

متن کامل

Hip resurfacing versus metal-on-metal total hip arthroplasty - are metal ion levels different?

A systematic review and meta-analysis of trials comparing hip resurfacing to metal-on-metal total hip arthroplasty was conducted to determine if there is a difference in serum metal ion levels in patients receiving these implants. EMBASE and MEDLINE databases were searched from inception to December 2010 for all trials involving the use of these devices. Eligibility for inclusion in the review ...

متن کامل

The Correlation of Serum Metal Ions with Functional Outcome Scores at Three-to-Six Years following Large Head Metal-on-Metal Hip Arthroplasty

Based on success of hip resurfacing, large head Metal on Metal (MoM) hip arthroplasty has gained significant popularity in recent years. There are growing concerns about metal ions related soft tissue abnormalities. The aim of this study was to define a correlation of metal ions with various functional outcome scores following large head MoM hip arthroplasty. Consecutive cohort of 70 patients (...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The Journal of bone and joint surgery. British volume

دوره 89 3  شماره 

صفحات  -

تاریخ انتشار 2007